Evidence map›Paper›PMID 32440107›Full record

ArticleClinical interventions in aging2020

The Role of Hip Abductor Strength in Identifying Older Persons at Risk of Falls: A Diagnostic Accuracy Study.

Simone Chantal Gafner, Caroline Henrice Germaine Bastiaenen, Serge Ferrari, Gabriel Gold, Andrea Trombetti, Philippe Terrier, Roger Hilfiker, Lara Allet

Open access · goldAbstract read
In one paragraph

Article in Clinical interventions in aging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Simone Chantal GafnerGeneva School of Health Sciences, HES-SO University of Applied Sciences and Arts Western Switzerland, Geneva, Switzerland.ORCID 0000-0003-4767-9789
Caroline Henrice Germaine BastiaenenDepartment of Epidemiology, Research Line Functioning and Rehabilitation, CAPHRI, Maastricht University, Maastricht, the Netherlands.ORCID 0000-0002-5083-6864
Serge FerrariDepartment of Internal Medicine Specialties, University Hospitals and University of Geneva, Geneva, Switzerland.
Gabriel GoldDepartment of Internal Medicine, Rehabilitation and Geriatrics, University Hospitals and University of Geneva, Geneva, Switzerland.
Andrea TrombettiDivision of Bone Diseases, Department of Medicine, University Hospitals and University of Geneva, Geneva, Switzerland.
Philippe TerrierSchool of Health Sciences, ARC Santé, HES-SO University of Applied Sciences and Arts Western Switzerland, Neuchâtel, Switzerland.ORCID 0000-0002-3693-4505
Roger HilfikerSchool of Health Sciences, HES-SO Valais-Wallis, University of Applied Sciences and Arts Western Switzerland, Valais, Switzerland.ORCID 0000-0001-8662-6116
Lara AlletGeneva School of Health Sciences, HES-SO University of Applied Sciences and Arts Western Switzerland, Geneva, Switzerland.ORCID 0000-0003-3260-7176
University of Geneva · CHHES-SO University of Applied Sciences and Arts Western Switzerland · CHHES-SO Valais-Wallis · CHMaastricht University · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND/

objectivesEarly detection of fall risk in persons older than 65 is of clinical relevance, but the diagnostic accuracy of currently used functional tests (eg short physical performance battery [SPPB] and timed up and go test [TUG]) to assess older persons' fall risks remains moderate. Recent literature highlights the importance of strong hip abductors to prevent falls. We thus aimed to assess the diagnostic accuracy of hip abductor strength measures to assess older persons' fall risks.

methodsHip abductor maximum voluntary isometric strength (ABD MVIS), rate of force generation (ABD RFG), and the SPPB and TUG functional fall risk assessments were assessed in 60 persons aged over 65 years (82.0 ± 6.1 years). The diagnostic accuracy (area under the curve [AUC], sensitivity [sens], specificity [spec], positive predictive value [PPV], negative predictive value [NPV], and positive and negative likelihood ratios [LR

resultsIn our population, hip ABD MVIS (AUC 0.8, sens 90.6%, spec 57.1%, PPV 70.7%, NPV 84.2%, LR+ 2.1, LR- 0.2, and cut-off value ≤ 1.1 N/kg) and hip ABD RFG (AUC 0.8, sens 90.6%, spec 46.4%, PPV 65.9%, NPV 81.3%, LR+ 1.7, LR- 0.2, and cut-off ≤ 8.47 N/kg/s) show diagnostic accuracy comparable to other fall risk assessments (SPPB and TUG) and a high net sensitivity when used in a test battery.

conclusionHip ABD MVIS or RFG shows good diagnostic accuracy to differentiate between older fallers and nonfallers compared to the chosen external criterion history of falls. The high net sensitivity when hip ABD MVIS or RFG is combined with currently used fall risk assessments shows promise in contributing value to a test battery and should be investigated further in longitudinal studies.

Indexed as

Accidental FallsAgedAged, 80 and overFemaleHip JointHumansIsometric ContractionMalePhysical Therapy ModalitiesRisk-TakingSensitivity and Specificityaccidental fallsagedfunctional performancehipmeasurement studymuscle strength

Identifiers

PMID32440107
PMCPMC7213876
OpenAlexW3022721474

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.