ArticleArtificial organs2020
Anti-clogging mechanisms of a motion-activated chest tube patency maintenance system: Histology and high-speed camera assessment.
Article in Artificial organs, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- Drainology: Leveraging research in chest-drain management to enhance recovery after cardiothoracic surgery.JTCVS techniques · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
Abstract
The motion-activated system (MAS) employs vibration to prevent intraluminal chest tube clogging. We evaluated the intraluminal clot formation inside chest tubes using high-speed camera imaging and postexplant histology analysis of thrombus. The chest tube clogging was tested (MAS vs. control) in acute hemothorax porcine models (n = 5). The whole tubes with blood clots were fixed with formalin-acetic acid solution and cut into cross-sections, proceeded for H&E-stained paraffin-embedded tissue sections (MAS sections, n = 11; control sections, n = 11), and analyzed. As a separate effort, a high-speed camera (FASTCAM Mini AX200, 100-mm Zeiss lens) was used to visualize the whole blood clogging pattern inside the chest tube cross-sectional view. Histology revealed a thin string-like fibrin deposition, which showed spiral eddy or aggregate within the blood clots in most sections of Group MAS, but not in those of the control group. Histology findings were compatible with high-speed camera views. The high-speed camera images showed a device-specific intraluminal blood "swirling" pattern. Our findings suggest that a continuous spiral flow in blood within the chest tube (MAS vs. static control) contributes to the formation of a spiral string-like fibrin network during consumption of coagulation factors. As a result, the spiral flow may prevent formation of thick band-like fibrin deposits sticking to the inner tube surface and causing tube clogging, and thus may positively affect chest tube patency and drainage.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.