Trial report in The British journal of radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.6field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 30 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Trial
  4. Trial
  5. Article
  6. Observational
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Hanan AlobeidiDepartment of Radiology, Örebro university Hospital, Region Örebro län, S-70185 Örebro, Sweden.ORCID http://orcid.org/0000-0001-8840-5229
Muhammed AlshamariDepartment of Radiology, Faculty of Medicine and Health, Örebro University, S-70182 Örebro, Sweden.
Jonas WidellDepartment of Radiology, Örebro university Hospital, Region Örebro län, S-70185 Örebro, Sweden.
Tomas ErikssonDepartment of Radiology, Örebro university Hospital, Region Örebro län, S-70185 Örebro, Sweden.
Mats LidénDepartment of Radiology, Faculty of Medicine and Health, Örebro University, S-70182 Örebro, Sweden.
Örebro University Hospital · SEÖrebro University · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo perform CT pulmonary angiography (CTPA) using a minimal amount of iodinated contrast media.

methods47 patients (25 females) with mean age 69 years (range 41-82 years) referred for contrast-enhanced chest CT were prospectively included in this Phase IV clinical drug trial. All participants underwent a study specific CTPA in addition to the chest CT. The participants received 80 mg I/kg body weight Iohexol contrast media using a preparatory saline bolus, a dual flow contrast/saline bolus and a saline flush, and a scanner protocol with 80 kVp dual source high-pitch mode. Three readers independently assessed the image quality on the 3-point scale non-diagnostic, adequate or good-excellent image quality. Additionally, the pulmonary arterial contrast opacification was measured.

resultsOn average, the patients received 16.8 ml Iohexol 350 mg I/mL (range 12-20 ml). Mean patient weight was 71 kg (range 50-85 kg). Identically for all readers, pulmonary embolism (PE) was detected in 1/47 participants. The median number of examinations visually scored concerning pulmonary embolism as good-excellent was 47/47 (range 44-47); adequate 0/47 (0-3) and non-diagnostic 0/47 (range 0-0). The proportion adequate or better examinations was for all readers 47/47, 100% [95% confidence interval 92-100%]. The mean attenuation ± standard deviation in the pulmonary trunk was 325 ± 72 Hounsfield unit (range 165-531 Hounsfield unit).

conclusionsDiagnostic CTPA with 17 ml contrast media is possible in non-obese patients using low kVp, high pitch and carefully designed contrast media administration. ADVANCES IN KNOWLEDGE: By combining several procedures in a CTPA protocol, the contrast media dose can be minimized.

Indexed as

AdultAgedAged, 80 and overClinical ProtocolsComputed Tomography AngiographyContrast MediaFemaleHumansIohexolMaleMiddle AgedPulmonary ArteryPulmonary EmbolismContrast MediaIohexol

Identifiers

PMID32436788
PMCPMC7336071
OpenAlexW3028583394

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked