ArticleJournal of applied clinical medical physics2020
A comprehensive and clinical-oriented evaluation criteria based on DVH information and gamma passing rates analysis for IMRT plan 3D verification.
Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- From 2D to 3D gamma passing rate tolerance and action limits for patient-specific quality assurance in volumetric-modulated arc therapy.Journal of applied clinical medical physics · 2025Article
- Evaluating AAPM-TG-218 recommendations: Gamma index tolerance and action limits in IMRT and VMAT quality assurance using SunCHECK.Journal of applied clinical medical physics · 2024Article
- A comprehensive site-specific analysis of patient-specific quality assurance based on dose volume histogram of RapidArc treatment delivery.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2024Article
- A structure-based gamma evaluation method for identifying clinically relevant dose differences in organs at risk.Physical and engineering sciences in medicine · 2023Article
- A method for patient-specific DVH verification using a high-sampling-rate log file in an Elekta linac.Journal of applied clinical medical physics · 2023Article
- [Impact of multi-leaf collimator positioning accuracy on quality control of volumetric modulation arc therapy plan for cervical cancer treated with Elekta linear accelerator].Nan fang yi ke da xue xue bao = Journal of Southern Medical University · 2022Article
- Assessment of Statistical Process Control Based DVH Action Levels for Systematic Multi-Leaf Collimator Errors in Cervical Cancer RapidArc Plans.Frontiers in oncology · 2022Article
- Optimizing the Region for Evaluation of Global Gamma Analysis for Nasopharyngeal Cancer (NPC) Pretreatment IMRT QA by COMPASS: A Retrospective Study.Frontiers in oncology · 2022Article
- DeltaJournal of medical physicsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo accomplish the 3D dose verification to IMRT plan by incorporating DVH information and gamma passing rates (GPs) (DVH_GPs) so as to better correlate the patient-specific quality assurance (QA) results with clinically relevant metrics. MATERIALS AND
methodsDVH_GPs analysis was performed to specific structures of 51 intensity-modulated radiotherapy (IMRT) treatment plans (17 plans each for oropharyngeal neoplasm, esophageal neoplasm, and cervical neoplasm) with Delta4 3D dose verification system. Based on the DVH action levels of 5% and GPs action levels of 90% (3%/2 mm), the evaluation results of DVH_GPs analysis were categorized into four regions as follows: the true positive (TP) (%DE> 5%, GPs < 90%), the false positive (FP) (%DE ≤ 5%, GPs < 90%), the false negative (FN) (%DE> 5%, GPs ≥ 90%), and the true negative (TN) (%DE ≤ 5%, GPs ≥ 90%). Considering the actual situation, the final patient-specific QA determination was made based on the DVH_GPs evaluation results. In order to exclude the impact of Delta4 phantom on the DVH_GPs evaluation results, 5 cm phantom shift verification was carried out to structures with abnormal results (femoral heads, lung, heart).
resultsIn DVH_GPs evaluation, 58 cases with FN, 5 cases with FP, and 2 cases with TP were observed. After the phantom shift verification, the extremely abnormal FN of both lung (%DE = 21.52%±8.20%) and heart (%DE = 19.76%) in the oropharyngeal neoplasm plans and of the bilateral formal heads (%DE = 26.41%±13.45%) in cervical neoplasm plans disappeared dramatically. DVH_GPs analysis was performed to all evaluation results in combination with clinical treatment criteria. Finally, only one TP case from the oropharyngeal neoplasm plans and one FN case from the esophageal neoplasm plans did not meet the treatment requirements, so they needed to be replanned.
conclusionThe proposed DVH_GPs evaluation method first make up the deficiency of conventional gamma analysis regarding intensity information and space information. Moreover, it improves the correlation between the patient-specific QA results and clinically relevant metrics. Finally, it can distinguish the TP, TN, FP, and FN in the evaluation results. They are affected by many factors such as the action levels of DVH and GPs, the feature of the specific structure, the QA device, etc. Therefore, medical physicist should make final patient-specific QA decision not only by taking into account the information of DVH and GPs, but also the practical situation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials