Evidence map›Paper›PMID 32435456›Full record

ArticleBone & joint research2020

Effects of condensation and compressive strain on implant primary stability: A longitudinal, in vivo, multiscale study in mice.

Zhijun Li, Masaki Arioka, Yindong Liu, Maziar Aghvami, Serdar Tulu, John B Brunski, Jill A Helms

Open access · goldAbstract read
In one paragraph

Article in Bone & joint research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 3 countries.

Zhijun LiDivision of Plastic and Reconstructive Surgery, Department of Surgery, Stanford School of Medicine, Stanford, California, USA; Orthopedic surgeon, Department of Orthopedics, Tianjin Medical University General Hospital, Tianjin, China.
Masaki AriokaDivision of Plastic and Reconstructive Surgery, Department of Surgery, Stanford School of Medicine, Stanford, California, USA; Assistant professor, Department of Clinical Pharmacology, Faculty of Medical Sciences, Kyushu University, Fukuoka, Japan.
Yindong LiuDivision of Plastic and Reconstructive Surgery, Department of Surgery, Stanford School of Medicine, Stanford, California, USA; Oral surgeon, State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
Maziar AghvamiDivision of Plastic and Reconstructive Surgery, Department of Surgery, Stanford School of Medicine, Stanford, California, USA.
Serdar TuluDivision of Plastic and Reconstructive Surgery, Department of Surgery, Stanford School of Medicine, Stanford, California, USA.
John B BrunskiDivision of Plastic and Reconstructive Surgery, Department of Surgery, Stanford School of Medicine, Stanford, California, USA.
Jill A HelmsDivision of Plastic and Reconstructive Surgery, Department of Surgery, Stanford School of Medicine, Stanford, California, USA.
Stanford Medicine · USState Key Laboratory of Oral DiseasesTianjin Medical University General Hospital · CN

Funding

Mechanobiology at Healing Bone-Implant InterfacesR01DE024000 · NIDCR · STANFORD UNIVERSITY · PI BRUNSKI, JOHN BEYER, HELMS, JILL A · 2014 to 2018
$3.4M
NIDCR NIH HHS R01 DE024000
6 · The paper itself

Abstract

aimsSurgeons and most engineers believe that bone compaction improves implant primary stability without causing undue damage to the bone itself. In this study, we developed a murine distal femoral implant model and tested this dogma.

methodsEach mouse received two femoral implants, one placed into a site prepared by drilling and the other into the contralateral site prepared by drilling followed by stepwise condensation.

resultsCondensation significantly increased peri-implant bone density but it also produced higher strains at the interface between the bone and implant, which led to significantly more bone microdamage. Despite increased peri-implant bone density, condensation did not improve implant primary stability as measured by an in vivo lateral stability test. Ultimately, the condensed bone underwent resorption, which delayed the onset of new bone formation around the implant.

conclusionCollectively, these multiscale analyses demonstrate that condensation does not positively contribute to implant stability or to new peri-implant bone formation.

Indexed as

BiomechanicalBone resorptionImplantOsseointegration

Identifiers

PMID32435456
PMCPMC7229305
OpenAlexW3009025798

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.