Evidence map›Paper›PMID 32435343›Full record

ArticleJournal of atrial fibrillation2019

4D Volume Intracardiac Echocardiography for Intraprocedural Guidance of Transcatheter Left Atrial Appendage Closure.

Houman Khalili, Marquand Patton, Haider Al Taii, Priya Bansal, Matthew Brady, Jeanellil Taylor, Arati Gurung, Brijeshwar Maini

Registry-linked trialOpen access · greenAbstract read
In one paragraph

Article in Journal of atrial fibrillation, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06061757 (Use of 4D Intracardiac Echocardiography), which is not on this map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.6field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06061757 narecruitingnot on this mapstarted 2023, after this paper: background citation

Use of 4D Intracardiac Echocardiography (4D-ICE) in Conjunction With Transesophageal Echocardiography (TEE) for Left Atrial Appendage Closure (LAAC)

TypeinterventionalSponsorKansas City Heart Rhythm Research FoundationRan2023 to 2025Enrolled52ConditionsAtrial Fibrillation, StrokeArmsImaging guidance with TEE and ICE for Left atrial appendage closure
3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 26 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Review
  5. Article
  6. Observational
  7. Review
  8. Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Houman KhaliliTenet Healthcare Corporation, Delray Beach, FL.
Marquand PattonTenet Healthcare Corporation, Delray Beach, FL.
Haider Al TaiiCharles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL.
Priya BansalCharles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL.
Matthew BradySiemens Healthineers, Malvern, PA.
Jeanellil TaylorSiemens Healthineers, Malvern, PA.
Arati GurungSiemens Healthineers, Malvern, PA.
Brijeshwar MainiTenet Healthcare Corporation, Delray Beach, FL.
Siemens Healthcare (United States) · USTenet Healthcare · USFlorida Atlantic University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFluoroscopy and transesophageal echocardiography (TEE) are used to guide transcatheter left atrial appendage (LAA) closure in patients with atrial fibrillation to prevent thromboembolic events. This study examines whether real-time three-dimensional volume ICE guidance (4D volume ICE) can be used as an alternative to TEE during LAA closure (LAAC). METHODS AND

resultsFifteen patients with atrial fibrillation (AF), who had high risk for stroke and contraindication for long-term warfarin therapy, were enrolled in the study. The WATCHMAN device was used for transcatheter LAAC under fluoroscopy. LAA and device sizing was performed using TEE and volume ICE guidance from the right heart. Intraprocedural ICE measurements were consistent with TEE; LAA maximal width and depth, and maximal diameter of the implanted device were moderately correlated (Pearson's coefficient: 0.63, 0.65, and 0.71 respectively; p<0.05) with good agreement (bias: -0.03 cm, -0.07 cm, and 0.003 cm respectively). The average imaging success rate, defined by the number of patients with all the required intraprocedural measurements, was 67% for ICE and 100% for TEE. The WATCHMAN device was successfully implanted in all patients with a device to patient ratio of 1.33.

conclusions4D volume ICE can be used as an intraprocedural sizing and guidance tool for transcatheter LAAC with measurements comparable to TEE. Challenging patient characteristics significantly degrade the diagnostic image quality when imaging from the right heart. Standardized workflow with proper patient selection and optimal preprocedural planning may improve the diagnostic quality of volume ICE guidance for transcatheter LAAC procedure.

Indexed as

ICELAA ClosureTEEWATCHMAN

Identifiers

PMID32435343
PMCPMC7237083
OpenAlexW3007840901

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.