Evidence map›Paper›PMID 32435340›Full record

ArticleJournal of atrial fibrillation2019

Implantation of BIV ICD with Near Zero Contrast Use in Patients with Advanced Renal Insufficiency Using Three Dimensional Electro-anatomical Mapping.

Adel Mina, Bradley Knight, Nicholas Warnecke

Open access · hybridAbstract read
In one paragraph

Article in Journal of atrial fibrillation, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 70% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Adel MinaUnityPoint Health Methodist Invasive Cardiology/Clinical Cardiac Electrophysiology Peoria, Illinois.
Bradley KnightUnityPoint Health Methodist Invasive Cardiology/Clinical Cardiac Electrophysiology Peoria, Illinois.
Nicholas WarneckeUnityPoint Health Methodist Invasive Cardiology/Clinical Cardiac Electrophysiology Peoria, Illinois.
Peoria campus of the University of Illinois System · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundBiventricular (BIV) ICD implantations are traditionally performed using contrast and fluoroscopic guidance. Contrast use in patient with advanced renal disease can cause deterioration of renal function and even lead to dialysis.

objectiveTo evaluate the feasibility of utilizing 3 D mapping technique in reducing or eliminating contrast use in patient with advanced renal disease. METHODS AND

resultsThe study consisted of 30 consecutive adult patients, in which BIV implantation was accomplished in advanced renal disease (stage III and IV GFR 15 to 59) by electroanatomical 3D mapping (EAM).Acute procedural success was 96% and only one patient LV lead implantation was unsuccessful due to unsuitable anatomy.47 % of patients had BIV ICD implantation with zero contrast. Average contrast exposure for the group was 4.3 ml only. Average ratio of contrast use to GFR (glomerular filtration rate) was only 0.1. Improved mean GFR was observed from 42 to 50 post procedure (P value<0.01), and continued to improve to 48 at 3 and 6 month (P value<0.01) and improvement decreased to 45 and 44 beyond 6 month and 1 year (P value NS). There was no single case of contrast induced acute renal insufficiency (CI-ARI) due to minimal use of contrast.69 % of the patients experienced an improvement in their functional class. A decrease in QRS duration was seen from 159 to 136 milliseconds (86% of patients had improved QRS duration); P value = <0.001. The average pre procedure ejection fraction (EF) for the group was 23%. The average EF post procedure for the group was 35%; P values = <0.001 (72% of patient had EF improvement).93% of patient had either EF and/or GFR improvement suggesting substantial clinical benefit from the procedure.There was no minor or major complications.

conclusionsImplantation of BiV ICD using EAM with near zero contrast is feasible, safe and effective in patients with moderate to severe renal insufficiency. There is an added renal protection and benefit from procedure in this group of patients.

Indexed as

Advanced renal diseaseBiV ICDNear Zero ContrastThree dimensional Electro-anatomical Mapping.

Identifiers

PMID32435340
PMCPMC7237082
OpenAlexW3007283142

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.