Commissioning of a 1.5T Elekta Unity MR-linac: A single institution experience.

Jeffrey E Snyder, Joël St-Aubin, Sridhar Yaddanapudi, Amanda Boczkowski, David A P Dunkerley, Stephen A Graves, Daniel E Hyer

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 56 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
56citing papers in PubMed, 2 pooled it
13.9field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

56 citing papers in PubMed, 2 syntheses or guidelines pooled it, 99 citations in OpenAlex.

  1. Guideline
  2. Guideline
  3. Review
  4. Article
  5. Article
  6. Evaluation of QUASAR Insight Phantom for daily imaging QA of MRgRT linacs.Journal of applied clinical medical physics · 2026
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Jeffrey E SnyderDepartment of Radiation Oncology, University of Iowa, Iowa City, IA, USA.
Joël St-AubinDepartment of Radiation Oncology, University of Iowa, Iowa City, IA, USA.
Sridhar YaddanapudiDepartment of Radiation Oncology, University of Iowa, Iowa City, IA, USA.
Amanda BoczkowskiDepartment of Radiation Oncology, University of Iowa, Iowa City, IA, USA.
David A P DunkerleyDepartment of Radiation Oncology, University of Iowa, Iowa City, IA, USA.
Stephen A GravesDepartment of Radiology, University of Iowa, Iowa City, IA, USA.
Daniel E HyerDepartment of Radiation Oncology, University of Iowa, Iowa City, IA, USA.
University of Iowa · US

Funding

Viral VectorP30CA086862 · NCI · UNIVERSITY OF IOWA · PI Mark E Burkard · 2000 to 2026
$70.0M
Project 4: New Approaches to Improving the Effectiveness of Radionuclide Targeted Treatments in Neuroendocrine TumorsP50CA174521 · NCI · UNIVERSITY OF IOWA · PI HOWE, JAMES R · 2015 to 2021
$13.2M
NCI NIH HHS P50 CA174521
6 · The paper itself

Abstract

MR image-guided radiotherapy has the potential to improve patient care, but integration of an MRI scanner with a linear accelerator adds complexity to the commissioning process. This work describes a single institution experience of commissioning an Elekta Unity MR-linac, including mechanical testing, MRI scanner commissioning, and dosimetric validation. Mechanical testing included multileaf collimator (MLC) positional accuracy, measurement of radiation isocenter diameter, and MR-to-MV coincidence. Key MRI tests included magnetic field homogeneity, geometric accuracy, image quality, and the accuracy of navigator-triggered imaging for motion management. Dosimetric validation consisted of comparison between measured and calculated PDDs and profiles, IMRT measurements, and end-to-end testing. Multileaf collimator positional accuracy was within 1.0 mm, the measured radiation isocenter walkout was 0.20 mm, and the coincidence between MR and MV isocenter was 1.06 mm, which is accounted for in the treatment planning system (TPS). For a 350-mm-diameter spherical volume, the peak-to-peak deviation of the magnetic field homogeneity was 4.44 ppm and the geometric distortion was 0.8 mm. All image quality metrics were within ACR recommendations. Navigator-triggered images showed a maximum deviation of 0.42, 0.75, and 3.0 mm in the target centroid location compared to the stationary target for a 20 mm motion at 10, 15, and 20 breaths per minute, respectively. TPS-calculated PDDs and profiles showed excellent agreement with measurement. The gamma passing rate for IMRT plans was 98.4 ± 1.1% (3%/ 2 mm) and end-to-end testing of adapted plans showed agreement within 0.4% between ion-chamber measurement and TPS calculation. All credentialing criteria were satisfied in an independent end-to-end test using an IROC MRgRT phantom.

Indexed as

Radiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedHumansMagnetic Resonance ImagingParticle AcceleratorsPhantoms, Imagingadaptive radiotherapycommissioningIMRTMRI-Linacunity

Identifiers

PMID32432405
PMCPMC7386194
OpenAlexW3026545984

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.