Evidence map›Paper›PMID 32430992›Full record

ArticleJournal of clinical laboratory analysis2020

FACSCanto II and LSRFortessa flow cytometer instruments can be synchronized utilizing single-fluorochrome-conjugated surface-dyed beads for standardized immunophenotyping.

Annelisa M Cornel, Christine A J van der Burght, Stefan Nierkens, Jeroen F van Velzen

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical laboratory analysis, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.3field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Annelisa M CornelCenter for Translational Immunology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.ORCID https://orcid.org/0000-0001-8349-121X
Christine A J van der BurghtCenter for Translational Immunology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.
Stefan NierkensCenter for Translational Immunology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.
Jeroen F van VelzenCenter for Translational Immunology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.
Utrecht University · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMultiparameter flow cytometry is the preferred method to determine immunophenotypic features of cells present in a wide variety of sample types. Standardization is key to avoid inconsistencies and subjectivity of interpretations between clinical diagnostic laboratories. Among these standardization requirements, synchronization between different flow cytometer instruments is indispensable to obtain comparable results. This study aimed to investigate whether two widely used flow cytometers, the FACSCanto II and LSRFortessa, can be effectively synchronized utilizing calibration bead-based synchronization.

methodTwo FACSCanto II and two LSRFortessa flow cytometers were synchronized with both multicolor hard-dyed and single-fluorochrome-conjugated surface-dyed beads according to the manufacturer's instructions. Cell staining was performed on five whole-blood samples obtained from healthy controls and were analyzed upon synchronization with the respective synchronization protocols.

resultsComparability criteria (defined as <15% deviation from the reference instrument) were met with both bead sets when synchronizing different FACSCanto II or LSRFortessa instruments. However, we observed that the criteria could not be met when synchronizing FACSCanto II with LSRFortessa instruments with multicolor hard-dyed beads. By utilizing single-fluorochrome-conjugated surface-dyed beads to determine and adjust PMT voltages, the accepted comparability criteria were successfully met. The protocol has been validated using five different eight-parameter stained samples.

conclusionWe show that FACSCanto II and LSRFortessa instruments can effectively be synchronized using single-fluorochrome-conjugated surface-dyed beads in case deviation criteria cannot be met using multicolor hard-dyed beads. Synchronization with single-fluorochrome-conjugated surface-dyed beads results in decreased deviations between instruments, allowing comparability criteria to become stricter.

Indexed as

CalibrationClinical Laboratory ServicesFlow CytometryFluorescent DyesHealthy VolunteersHumansImmunophenotypingFluorescent DyesFACSCanto IIflow cytometryimmunophenotypingLSRFortessamulticenter comparabilitystandardization

Identifiers

PMID32430992
PMCPMC7521264
OpenAlexW3026808948

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390