ReviewInsights into imaging2020
Dynamic MRI for articulating joint evaluation on 1.5 T and 3.0 T scanners: setup, protocols, and real-time sequences.
Review in Insights into imaging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 29 citations in OpenAlex.
- Preliminary Evaluation of Static and Kinematic Magnetic Resonance Imaging (MRI) of the Feline Temporomandibular Joint (TMJ): A Comparative Analysis of Joint Inclination Angles in Intact and Dislocated Conditions.Veterinary sciences · 2026Article
- Real-time 3-T MRI of peroneal tendon motion during active ankle movement: feasibility and image quality.European radiology experimental · 2026Article
- Extending real-time MRI of the oral cavity using simultaneous multislice and compressed sensing.Magnetic resonance in medicine · 2026Article
- Auto-segmentation of thoraco-abdominal organs in pediatric dynamic MRI.Medical physics · 2025Article
- Sports Radiology: A Key Driver of Clinical Decision-Making.Diagnostics (Basel, Switzerland) · 2025Article
- Insights of cartilage imaging in cartilage regeneration.World journal of orthopedics · 2025Review
- Injury of the posterolateral corner of the knee does not lead to higher intra-articular external tibial rotation in the MRI.Journal of experimental orthopaedics · 2025Article
- Peroneus brevis split rupture is underreported on magnetic resonance imaging of the ankle in patients with chronic lateral ankle pain.European journal of radiology open · 2024Article
- Anterior-posterior glenohumeral translation in shoulders with traumatic anterior instability: a systematic review of the literature.JSES reviews, reports, and techniques · 2023Review
- MR-Imaging in Osteoarthritis: Current Standard of Practice and Future Outlook.Diagnostics (Basel, Switzerland) · 2023Review
- A novel multipurpose device for guided knee motion and loading during dynamic magnetic resonance imaging.Zeitschrift fur medizinische Physik · 2022Article
- Development of Real-Time Kinematic Magnetic Resonance Imaging (kMRI) Techniques for Studying the Kinematics of the Spine and Joints in Dogs-Preliminary Study on Cadavers.Animals : an open access journal from MDPI · 2022Article
- Comprehensive personalized ankle joint shape analysis of children with cerebral palsy from pediatric MRI.Frontiers in bioengineering and biotechnology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Dynamic magnetic resonance imaging (MRI) is a non-invasive method that can be used to increase the understanding of the pathomechanics of joints. Various types of real-time gradient echo sequences used for dynamic MRI acquisition of joints include balanced steady-state free precession sequence, radiofrequency-spoiled sequence, and ultra-fast gradient echo sequence. Due to their short repetition time and echo time, these sequences provide high temporal resolution, a good signal-to-noise ratio and spatial resolution, and soft tissue contrast. The prerequisites of the evaluation of joints with dynamic MRI include suitable patient installation and optimal positioning of the joint in the coil to allow joint movement, sometimes with dedicated coil support. There are currently few recommendations in the literature regarding appropriate protocol, sequence standardizations, and diagnostic criteria for the use of real-time dynamic MRI to evaluate joints. This article summarizes the technical parameters of these sequences from various manufacturers on 1.5 T and 3.0 T MRI scanners. We have reviewed pertinent details of the patient and coil positioning for dynamic MRI of various joints. The indications and limitations of dynamic MRI of joints are discussed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.