Evidence map›Paper›PMID 32430036›Full record

ArticleJournal of neuroengineering and rehabilitation2020

Functional movement assessment by means of inertial sensor technology to discriminate between movement behaviour of healthy controls and persons with knee osteoarthritis.

Rob van der Straaten, Mariska Wesseling, Ilse Jonkers, Benedicte Vanwanseele, Amber K B D Bruijnes, Jan Malcorps, Johan Bellemans, Jan Truijen, Liesbet De Baets, Annick Timmermans

Open access · goldAbstract read
In one paragraph

Article in Journal of neuroengineering and rehabilitation, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 1 pooled it
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 1 synthesis or guideline pooled it, 24 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Observational
  6. Article
  7. Review
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 1 country.

Rob van der StraatenREVAL Rehabilitation Research Center, Hasselt University, Diepenbeek, Belgium. rob.vanderstraaten@uhasselt.be.ORCID 0000-0002-5071-2124
Mariska WesselingDepartment of Movement Sciences, Human Movement Biomechanics, KU Leuven, Leuven, Belgium.
Ilse JonkersDepartment of Movement Sciences, Human Movement Biomechanics, KU Leuven, Leuven, Belgium.
Benedicte VanwanseeleDepartment of Movement Sciences, Human Movement Biomechanics, KU Leuven, Leuven, Belgium.
Amber K B D BruijnesDepartment of Orthopaedics, Ziekenhuis Oost-Limburg, Genk, Belgium.
Jan MalcorpsDepartment of Orthopaedic Surgery, Jessa Hospital, Hasselt, Belgium.
Johan BellemansDepartment of Orthopaedics, Ziekenhuis Oost-Limburg, Genk, Belgium.
Jan TruijenDepartment of Orthopaedics, Ziekenhuis Oost-Limburg, Genk, Belgium.
Liesbet De BaetsREVAL Rehabilitation Research Center, Hasselt University, Diepenbeek, Belgium.
Annick TimmermansREVAL Rehabilitation Research Center, Hasselt University, Diepenbeek, Belgium.
Hasselt University · BEKU Leuven · BEZiekenhuis Oost-Limburg · BEJessa Hospital · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundApart from biomechanical alterations in movement patterns, it is known that movement limitations in persons with knee osteoarthritis (PwKOA) are related to an individual's perception and belief regarding pain and disability. To gain more insights into the functional movement behaviour of PwKOA in a clinical setting, inertial sensor technology can be applied. This study first aims to evaluate the ability of inertial sensors to discriminate between healthy controls (HC) and PwKOA. Secondly, this study aims to determine the relationship between movement behaviour, pain-related factors and disability scores.

methodsTwelve HC and 19 PwKOA were included. Five repetitions of six functional movement tasks (walking, forward lunge, sideward lunge, ascent and descent stairs, single leg squat and sit-to-stand) were simultaneously recorded by the inertial sensor system and a camera-based motion analysis system. Statistically significant differences in angular waveforms of the trunk, pelvis and lower limb joints between HC and PwKOA were determined using one-dimensional statistical parametric mapping (SPM1D). The Knee injury and Osteoarthritis Outcome Score and TAMPA scale for Kinesiophobia were used to evaluate the relationship between discriminating joint motion, pain-related factors and disability using spearman's correlation coefficients.

resultsPwKOA had significantly less trunk rotation, internal pelvis rotation and knee flexion ROM during walking. Additionally, the reduced knee flexion (i.e. at the end of the stance phase and swing phase) was related to increased level of perceived pain. During the sideward lunge, PwKOA had significantly less knee flexion, ankle plantarflexion and hip abduction. This decreased hip abduction (i.e. during stance) was related to higher fear of movement. Finally, PwKOA had significantly less knee flexion during the forward lunge, single leg squat and during ascent and descent stairs. No significant correlations were observed with disability.

conclusionsInertial sensors were able to discriminate between movement characteristics of PwKOA and HC. Additionally, significant relationships were found between joint motion, perceived pain and fear of movement. Since inertial sensors can be used outside the laboratory setting, these results are promising as they indicate the ability to evaluate movement deviations. Further research is required to enable measurements of small movement deviations in clinically relevant tasks.

Indexed as

Wearable Electronic DevicesAccelerometryAgedBiomechanical PhenomenaFemaleHumansKnee JointLower ExtremityMaleMiddle AgedMotor ActivityOsteoarthritis, KneeAmbulatoryFear of movementFunctional movementInertial sensorsMotion-analysisOsteoarthritisPainQuestionnairesRepeatabilityValidation

Identifiers

PMID32430036
PMCPMC7236325
OpenAlexW3028528101

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked