Evidence map›Paper›PMID 32429089›Full record

ArticleMaterials (Basel, Switzerland)2020

Geometric Analysis of Type B Aortic Dissections Shows Aortic Remodeling After Intervention Using Multilayer Stents.

Victor S Costache, Jorn P Meekel, Andreea Costache, Tatiana Melnic, Crina Solomon, Anca M Chitic, Cristian Bucurenciu, Horatiu Moldovan, Iulian Antoniac, Gabriela Candea and 1 more

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.9field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 3 institutions in 2 countries.

Victor S CostacheNextCardio Project, Lucian Blaga University of Sibiu, 550024 Sibiu, Romania.
Jorn P MeekelNextCardio Project, Lucian Blaga University of Sibiu, 550024 Sibiu, Romania.ORCID 0000-0002-4716-8041
Andreea CostacheNextCardio Project, Lucian Blaga University of Sibiu, 550024 Sibiu, Romania.
Tatiana MelnicNextCardio Project, Lucian Blaga University of Sibiu, 550024 Sibiu, Romania.
Crina SolomonNextCardio Project, Lucian Blaga University of Sibiu, 550024 Sibiu, Romania.
Anca M ChiticNextCardio Project, Lucian Blaga University of Sibiu, 550024 Sibiu, Romania.
Cristian BucurenciuNextCardio Project, Lucian Blaga University of Sibiu, 550024 Sibiu, Romania.
Horatiu MoldovanDepartment of Cardiac Surgery, Titu Maiorescu University, 040441 Bucharest, Romania.
Iulian AntoniacMaterials Science and Engineering Faculty, University Politehnica of Bucharest, 060042 Bucharest, Romania.ORCID 0000-0003-0112-3494
Gabriela CandeaNextCardio Project, Lucian Blaga University of Sibiu, 550024 Sibiu, Romania.
Kak K YeungNextCardio Project, Lucian Blaga University of Sibiu, 550024 Sibiu, Romania.
Lucian Blaga University of Sibiu · ROTitu Maiorescu University · ROUniversitatea Națională de Știință și Tehnologie Politehnica București · RO

Funding

Competitiveness Operational Programme 2014-2020, European Regional Development Fund and by the Romanian Government COP P_37_701
6 · The paper itself

Abstract

Recently, multilayer stents for type B aortic dissections (TBAD) have been proposed to decrease false lumen flow, increase and streamline true lumen flow, and retain branch vessel patency. We aimed to provide a protocol with standardized techniques to investigate aortic remodeling of TBAD by multilayer flow modulators (MFM) in static geometric and hemodynamic analyses. Combining existing literature and new insights, a standardized protocol was designed. Using pre- and postoperative CT scans, geometric models were constructed, lumen dimensions were calculated, computational fluid dynamics (CFD) models were composed, and velocity and pressures were calculated. Sixteen TBAD cases treated with MFM were included for analysis. For each case, aortic remodeling was analyzed using post-processing medical imaging software. After 3D models were created, geometrical anatomical measurements were performed, and meshes for finite element analysis were generated. MFM cases were compared pre- and postoperatively; true lumen volumes increased (

Indexed as

aortic dissectionaortic remodelingcomputational fluid dynamicsgeometric analysismultilayer flow modulator

Identifiers

PMID32429089
PMCPMC7287707
OpenAlexW3025527344

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.