ArticleEuropean radiology2020

Combined use of virtual monochromatic images and projection-based metal artifact reduction methods in evaluation of total knee arthroplasty.

Hee-Dong Chae, Sung Hwan Hong, Mack Shin, Ja-Young Choi, Hye Jin Yoo

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Advances in Bone Joint Imaging-Metal Artifact Reduction.Diagnostics (Basel, Switzerland) · 2022
    Review
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hee-Dong ChaeDepartment of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
Sung Hwan HongDepartment of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea. drhong@snu.ac.kr.ORCID http://orcid.org/0000-0003-2302-1341
Mack ShinDepartment of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
Ja-Young ChoiDepartment of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
Hye Jin YooDepartment of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo evaluate the effect of the combined use of virtual monochromatic imaging (VMI) and projection-based metal artifact reduction (PB-MAR) methods on further artifact reduction and image quality in total knee arthroplasty (TKA) patients.

methodsFifty-seven knee joints from 36 patients who had a previous history of TKA for bilateral or unilateral knee joints were included in this study. Four sets of images were compared between non-MAR, PB-MAR, VMI, and VMI + PB-MAR. For quantitative analysis, the area, mean attenuation, artifact index (AI), and contrast-to-noise ratio (CNR) were calculated for each protocol. Regarding qualitative analysis, overall artifact and depiction of soft tissue and bony structure were compared using relative visual grading analysis.

resultsIn the femoral region, the VMI + PB-MAR protocol showed the best MAR performance in quantitative measures including area, mean attenuation, and AI (p < .001). However, MAR protocols with VMI showed significantly lower CNRs than did the protocols without VMI in the tibial region (p < .001). On qualitative analysis, VMI + PB-MAR also showed fewer overall artifacts than did the other two MAR protocols. Soft tissue was best depicted in VMI + PB-MAR protocol, and PB-MAR showed the best performance for the depiction of bony structure (p < .001).

conclusionsThe combined use of VMI and PB-MAR showed better MAR performance than did PB-MAR or VMI alone. In areas with severe metal artifacts, the VMI + PB-MAR and PB-MAR protocols were useful for the evaluation of soft tissue and bone structure, respectively. KEY POINTS: • The combination of artifact reduction methods is effective in reducing metal artifacts in CT. • Soft tissue was best depicted in the combined protocol of projection- and dual-energy-based methods, and projection-based protocol showed the best performance for the depiction of bone structure in case of severe metal artifacts.

Indexed as

AlgorithmsArthroplasty, Replacement, KneeArtifactsAgedAged, 80 and overFemaleHumansMaleMetalsMiddle AgedRadiographic Image Interpretation, Computer-AssistedTomography, X-Ray ComputedMetalsArthroplasty, replacement, kneeArtifactsImage processing, computer-assistedKnee prosthesisTomography, X-ray computed