A comparison of cine CMR imaging at 0.55 T and 1.5 T.
Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 31 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Technical Development of Cardiovascular Magnetic Resonance Imaging (CMR) Using a Low Specific Absorption Rate (SAR) Scanner System
Technical and Translational Development of Cardiovascular MRI (CMR)
Who cites it
31 citing papers in PubMed, 1 synthesis or guideline pooled it, 51 citations in OpenAlex.
- Society for Cardiovascular Magnetic Resonance recommendations toward environmentally sustainable cardiovascular magnetic resonance.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025Guideline
- 4D Flow MRI at 0.6 T-Self-Gating Versus Camera-Based Respiratory Binning.Bioengineering (Basel, Switzerland) · 2026Article
- Acceleration of slice encoding for metal artifact correction at 0.55 T using hexagonal sampling.Magnetic resonance in medicine · 2026Article
- Feasibility of Golden Angle Spiral Real-Time Phase Contrast MRI at 0.55T: A Single-Center Prospective Study.Bioengineering (Basel, Switzerland) · 2026Article
- Liver fat quantification at 0.55 T enabled by locally low-rank enforced deep learning reconstruction.Magnetic resonance in medicine · 2026Article
- Safety and Engraftment of Aligned Cardiac Patches Loaded with hiPSC-CMs in a Large Animal Model of Myocardial Infarction.Theranostics · 2026Article
- Low-field and portable MRI technology: advancements and innovations.European radiology experimental · 2025Review
- Feasibility of Noncontrast 3D MR Angiography on a Commercial Wide-Bore 0.55-T System: Comparison with 1.5-T MR Angiography.Radiology. Cardiothoracic imaging · 2025Article
- Multidimensional RF pulse design with consideration of concomitant field effects.Magnetic resonance in medicine · 2025Article
- Measuring biventricular function and left atrial volume in a single five-dimensional whole-heart cardiovascular magnetic resonance scan at 0.55T.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025Article
- Cardiac Cine MRI Using a Commercially Available 0.55-T Scanner.Radiology. Cardiothoracic imaging · 2024Article
- Next-Generation Cardiac Magnetic Resonance Imaging Techniques for Characterization of Myocardial Disease.Current treatment options in cardiovascular medicine · 2024Article
- Cardiovascular Imaging, Climate Change, and Environmental Sustainability.Radiology. Cardiothoracic imaging · 2024Review
- Cardiac MRI at Low Field Strengths.Journal of magnetic resonance imaging : JMRI · 2024Review
- New clinical opportunities of low-field MRI: heart, lung, body, and musculoskeletal.Magma (New York, N.Y.) · 2024Review
- Structural and functional fetal cardiac imaging using low field (0.55 T) MRI.Frontiers in pediatrics · 2024Article
- Non-invasive pressure-volume loops using the elastance model and CMR: a porcine validation at transient pre-loads.European heart journal. Imaging methods and practice · 2024Article
- Endograft position and endoleak detection after endovascular abdominal aortic repair with low-field tiltable MRI: a feasibility study.European radiology experimental · 2023Article
- Feasibility of Free-Breathing, Non-ECG-Gated, Black-Blood Cine Magnetic Resonance Images With Multitasking in Measuring Left Ventricular Function Indices.Korean journal of radiology · 2023Article
- Low-field MRI: A report on the 2022 ISMRM workshop.Magnetic resonance in medicine · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundThere is a renewed interest in lower field magnetic resonance imaging (MRI) systems for cardiovascular magnetic resonance (CMR), due to their favorable physical properties, reduced costs, and increased accessibility to patients with implants. We sought to assess the diagnostic capabilities of high-performance low-field (0.55 T) CMR imaging for quantification of right and left ventricular volumes and systolic function in both healthy subjects and patients referred for clinical CMR.
methodsSixty-five subjects underwent paired exams at 1.5 T using a clinical CMR scanner and using an identical CMR system modified to operate at 0.55 T. Volumetric coverage of the right ventricle (RV) and left ventricles (LV) was obtained using either a breath-held cine balanced steady-state free-precession acquisition or a motion-corrected free-breathing re-binned cine acquisition. Bland-Altman analysis was used to compare LV and RV end-systolic volume (ESV), end-diastolic volume (EDV), ejection fraction (EF), and LV mass. Diagnostic confidence was scored on a Likert-type ordinal scale by blinded readers.
resultsThere were no significant differences in LV and RV EDV between the two scanners (e.g., LVEDV: p = 0.77, bias = 0.40 mL, correlation coefficient = 0.99; RVEDV: p = 0.17, bias = - 1.6 mL, correlation coefficient = 0.98), and regional wall motion abnormality scoring was similar (kappa 0.99). Blood-myocardium contrast-to-noise ratio (CNR) at 0.55 T was 48 ± 7% of the 1.5 T CNR, and contrast was sufficient for endocardial segmentation in all cases. Diagnostic confidence of images was scored as "good" to "excellent" for the two field strengths in the majority of studies.
conclusionA high-performance 0.55 T system offers good bSSFP CMR image quality, and quantification of biventricular volumes and systolic function that is comparable to 1.5 T in patients.
trial registrationClinicaltrials.gov NCT03331380, NCT03581318.