ArticlePolymers2020
Closed-Form Solution and Experimental Verification for the Axisymmetric Deformation Problem of Blistering Circular Thin Polymer Films under Uniformly Distributed Gas Pressure.
Article in Polymers, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Large Deflection Analysis of Peripherally Fixed Circular Membranes Subjected to Liquid Weight Loading: A Refined Design Theory of Membrane Deflection-Based Rain Gauges.Materials (Basel, Switzerland) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
The existing studies indicate that the measurement formulas used in blister test techniques, which are used to measure the mechanical properties of thin-film/substrate systems, are usually given based on an approximation-that is, the applied direction of the uniformly distributed transverse load is always vertical, while the applied direction of the uniformly distributed gas pressure is always perpendicular to the surface of the thin film. This approximation will lead to a large measurement error. In this study, we obtained the analytical solution to the problem of axisymmetric deformation of blistering circular thin polymer films under the action of uniformly distributed gas pressure via the power series method. An example is given to illustrate the error caused by the approximation mentioned above, and the validity of the solution presented here is verified. The result shows that the chance of error caused by the approximation increases with the increase in the applied load, and it far exceeds the allowable error of measurement when the applied load is relatively large. In addition, the related experiments of the blistering circular thin polymer film under uniformly distributed gas pressure are carried out, and the experimental results are compared with the theoretical results. The comparison results show that the analytical solution given in this paper is correct. The solution presented here is of great significance to improve the measurement accuracy of the blister test technique.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.