False-negative results on computer-aided detection software in preoperative automated breast ultrasonography of breast cancer patients.

Youngjune Kim, Jiwon Rim, Sun Mi Kim, Bo La Yun, So Yeon Park, Hye Shin Ahn, Bohyoung Kim, Mijung Jang

Open access · diamondAbstract read
In one paragraph

Article in Ultrasonography (Seoul, Korea), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Youngjune KimDepartment of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea.
Jiwon RimDepartment of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea.
Sun Mi KimDepartment of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea.
Bo La YunDepartment of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea.
So Yeon ParkDepartment of Pathology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.
Hye Shin AhnDepartment of Radiology, Chung-Ang University Hospital,ChungAng University College of Medicine, Seoul, Korea.
Bohyoung KimDivision of Biomedical Engineering, Hankuk University of Foreign Studies, Yongin, Korea.
Mijung JangDepartment of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea.
Seoul National University Bundang Hospital · KRChung-Ang University Hospital · KRHankuk University of Foreign Studies · KRSeoul National University · KR

Funding

Seoul National University
6 · The paper itself

Abstract

purposeThe purpose of this study was to measure the cancer detection rate of computer-aided detection (CAD) software in preoperative automated breast ultrasonography (ABUS) of breast cancer patients and to determine the characteristics associated with false-negative outcomes.

methodsA total of 129 index lesions (median size, 1.7 cm; interquartile range, 1.2 to 2.4 cm) from 129 consecutive patients (mean age±standard deviation, 53.4±11.8 years) who underwent preoperative ABUS from December 2017 to February 2018 were assessed. An index lesion was defined as a breast cancer confirmed by ultrasonography (US)-guided core needle biopsy. The detection rate of the index lesions, positive predictive value (PPV), and false-positive rate (FPR) of the CAD software were measured. Subgroup analysis was performed to identify clinical and US findings associated with false-negative outcomes.

resultsThe detection rate of the CAD software was 0.84 (109 of 129; 95% confidence interval, 0.77 to 0.90). The PPV and FPR were 0.41 (221 of 544; 95% CI, 0.36 to 0.45) and 0.45 (174 of 387; 95% CI, 0.40 to 0.50), respectively. False-negative outcomes were more frequent in asymptomatic patients (P<0.001) and were associated with the following US findings: smaller size (P=0.001), depth in the posterior third (P=0.002), angular or indistinct margin (P<0.001), and absence of architectural distortion (P<0.001).

conclusionThe CAD software showed a promising detection rate of breast cancer. However, radiologists should judge whether CAD software-marked lesions are true- or false-positive lesions, considering its low PPV and high FPR. Moreover, it would be helpful for radiologists to consider the characteristics associated with false-negative outcomes when reading ABUS with CAD.

Indexed as

Automated breast ultrasoundBreast neoplasmsComputer-assisted detectionUltrasonography

Identifiers

PMID32422696
PMCPMC7758101
OpenAlexW3013003005

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.