Evidence map›Paper›PMID 32415416›Full record

Observational studyInternational orthopaedics2020

A novel calibration method for digital templating of total hip arthroplasty: a prospective clinical study of dual scale type single marker calibration in supine radiographs.

Lennard Loweg, Matthias Trost, Karl Philipp Kutzner, Christian Ries, Christoph Kolja Boese

Abstract readObservational Study
PubMed Publisher
In one paragraph

Observational study in International orthopaedics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.6field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Observational
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 1 country.

Lennard LowegDepartment of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Wiesbaden, Germany.
Matthias TrostDepartment of Orthopaedics and Traumatology, St. Josef-Hospital, Ruhr University Bochum, Bochum, Germany.
Karl Philipp KutznerDepartment of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Wiesbaden, Germany.
Christian RiesDepartment of Orthopaedics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Christoph Kolja BoeseDepartment of Orthopaedic and Trauma Surgery, University Hospital of Cologne, Joseph-Stelzmann-Str. 9, 50924, Cologne, Germany. christoph.boese@uk-koeln.de.ORCID 0000-0002-5050-9345
St. Josefs Hospital · DESt. Josef-Hospital · DEUniversität Hamburg · DEUniversity Hospital Cologne · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundExternal calibration markers (ECM) are the standard of care for digital templating in joint replacements. Spherical mono markers are known to be unreliable. Fixed calibration factors (FCF) can reduce the overall error by placement of markers, but do not address individual patient anatomy. Dual scale calibration marker (DSCM) methods were developed to improve precision of calibration but require two markers. This prospective observational study is the first to analyse the application of a dual scale type single marker (DSSM) method in supine radiographs.

methodsOne hundred patients with unilateral total hip arthroplasty (THA) underwent anterior-posterior pelvis X-ray with ECM and DSSM. The femoral THA head components were used as internal reference (ICM). An empirical fixed calibration factor (FCF; 120%) was used as comparator. Absolute differences of ICM and both ECM and DSSM were calculated. Absolute relative deviations (ARD) were calculated.

resultsMean absolute calibration factor differences of ECM, FCF and DSSM from ICM were 0.105 (0.002-0.182), 0.016 (0.082-0.013) and 0.011 (0.056-0.009), respectively. ARD differences between ECM and DSSM as well as FCF and DSSM were significant (p < 0.001).

conclusionThe DSSM method showed superior results over ECM and FCF to predict the optimal calibration factor in supine radiographs. The novel DSSM method could be used to improve digital templating in supine radiographs without need for additional markers.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisCalibrationHip JointHumansProspective StudiesReproducibility of ResultsCalibrationDigital radiographDigital templatingHip replacementTotal hip arthroplasty

Identifiers

PMID32415416
OpenAlexW3024970681

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.