Evidence map›Paper›PMID 32415412›Full record

ArticleOral and maxillofacial surgery2020

Repair of orbital floor fractures via the transantral approach with osteosynthesis plate.

Alexander S Pankratov, Zauri P Gotsiridze, Artur N Kondrat, Anatolij V Karalkin

Abstract read
PubMed Publisher
In one paragraph

Article in Oral and maxillofacial surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Alexander S PankratovDepartment of Maxillofacial Surgery, I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia. stomat-2008@mail.ru.ORCID https://orcid.org/0000-0001-9620-3547
Zauri P GotsiridzeDepartment of Maxillofacial Surgery, First Moscow Municipal Clinical Hospital named N.Y. Pirogov, Moscow, Russia.
Artur N KondratDepartment of Maxillofacial Surgery, First Moscow Municipal Clinical Hospital named N.Y. Pirogov, Moscow, Russia.
Anatolij V KaralkinDepartment of Radiology, Russian Medical Academy of Continuous Professional Education, Moscow, Russia.
City Clinical Hospital · RURussian Medical Academy of Continuous Professional Education · RUSechenov University · RU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe most common surgical access techniques employed in patients with orbital floor fractures are associated with a risk of complications, such as implant infection, migration, epiphora, lower eyelid retraction, ectropion, diplopia worsening, retrobulbar hematoma, emphysema, "white-eyed" syndrome, enophthalmia relapse, hypoglobus, and persistent diplopia due to periorbital atrophy. Consequently, alternative access techniques precluding these complications have to be found. STUDY

objectiveTo assess the efficacy of transantral approach in the surgical treatment of patients with orbital floor fractures based on results of retrospective analysis of our clinical experience. MATERIALS AND

methodsWe performed a retrospective study of medical records and X-ray data of 52 patients with fractures of the floor of the orbit, 18 to 68 years old, treated using transantral approach as described in the article. Titanium plates of special shape were used for orbital floor reconstruction.

resultsIn 94.2% of the cases, adequate restoration of the floor of the orbit was achieved. It led to regression of the ocular signs. In 4 patients, diplopia remained in extreme gaze positions, which did not require surgical correction. The failed cases were related to incorrect positioning of the plate or fixing screws. No inflammatory complications were observed.

conclusionTransantral access approach may be a technique of choice in treating patients with orbital floor fractures; it is safe, minimally traumatic, and effective in the early posttraumatic period when the injured area is located in the posterior parts of the floor of the orbit.

Indexed as

OrbitOrbital FracturesAdolescentAdultAgedBone PlatesFracture Fixation, InternalHumansMiddle AgedRetrospective StudiesYoung AdultFractureOrbitTransantral approach

Identifiers

PMID32415412
OpenAlexW3025046959

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.