Evidence map›Paper›PMID 32413872›Full record

ArticlePhysics in medicine and biology2020

Prismatoid light guide array for enhanced gamma ray localization in PET: a Monte Carlo simulation study of scintillation photon transport.

Andy LaBella, Wei Zhao, Rick Lubinsky, Amir H Goldan

Open access · greenAbstract readLetter
In one paragraph

Article in Physics in medicine and biology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.7field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Decision Tree-Based Demultiplexing for Prism-PET.IEEE transactions on nuclear science · 2023
    Article
  6. Article
  7. Article
  8. Performance of Dual-Ended Readout PET Detectors Based on BGO Arrays and BaSOIEEE transactions on radiation and plasma medical sciences · 2022
    Article
  9. Article
  10. High-Resolution Depth-Encoding PET Detector Module with Prismatoid Light-Guide Array.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Andy LaBellaDepartment of Biomedical Engineering, Stony Brook University, Stony Brook, NY, United States of America.ORCID 0000-0002-3510-0322
Wei ZhaoDepartment of Radiology, Stony Brook University, Stony Brook, NY, United States of America.
Rick LubinskyDepartment of Radiology, Stony Brook University, Stony Brook, NY, United States of America.ORCID 0000-0002-9985-2662
Amir H GoldanDepartment of Radiology, Stony Brook University, Stony Brook, NY, United States of America.ORCID 0000-0001-6513-5801
Stony Brook University · US

Funding

Selenium Solid-State Photomultiplier (Se-SSPM): Towards a Low-Cost MR-Compatible Time-Of-Flight PETR21EB024849 · NIBIB · STATE UNIVERSITY NEW YORK STONY BROOK · PI GOLDAN, AMIRHOSSEIN · 2017 to 2018
$433k
NIBIB NIH HHS R21 EB024849
6 · The paper itself

Abstract

High spatial resolution PET relies on having excellent depth-of-interaction (DOI) resolution and small detector elements. Depth-encoding in PET modules has traditionally been performed using dual-ended readout. In recent years, researchers have explored the feasibility of replacing the second readout array with a light guide at the entrance layer that introduces intercrystal light sharing in order to reduce cost and and make depth-encoding modules more compact. However, single-ended readout depth-encoding modules have suboptimal and non-uniform crystal separation and DOI performance due to the random light sharing patterns of the uniform light guide, resulting in degraded peformance along the edges and corners of the detector arrays. In this paper, we introduce and characterize a segmented light guide composed of an array of prism mirrors which introduce deterministic intercrystal light sharing in single-ended readout PET detectors. We determined the expected spatial performance of our modules with our light guide using optical ray tracing Monte Carlo simulations. We demonstrate that having controlled, deterministic light sharing improves both DOI and crystal identification performance, enabling uniform spatial performance throughout the detector array. Designed specifically for high resolution PET, our prismatoid light guide array can be used to build cost-effective total-body and organ-dedicated PET systems with single-ended readout depth-encoding modules.

Indexed as

Gamma RaysMonte Carlo MethodPhotonsEquipment DesignPositron-Emission Tomography

Identifiers

PMID32413872
PMCPMC11025681
OpenAlexW3025149470

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.