Evidence map›Paper›PMID 32411276›Full record

ArticleComputational and mathematical methods in medicine2020

Magnetic Resonance Image Denoising Algorithm Based on Cartoon, Texture, and Residual Parts.

Yanqiu Zeng, Baocan Zhang, Wei Zhao, Shixiao Xiao, Guokai Zhang, Haiping Ren, Wenbing Zhao, Yonghong Peng, Yutian Xiao, Yiwen Lu and 2 more

Abstract read
In one paragraph

Article in Computational and mathematical methods in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Yanqiu ZengChengyi University College, Jimei University, Xiamen, China.ORCID https://orcid.org/0000-0003-4069-6957
Baocan ZhangChengyi University College, Jimei University, Xiamen, China.
Wei ZhaoChengyi University College, Jimei University, Xiamen, China.ORCID https://orcid.org/0000-0002-6814-1526
Shixiao XiaoChengyi University College, Jimei University, Xiamen, China.
Guokai ZhangSchool of Software Engineering, Tongji University, Shanghai, China.ORCID https://orcid.org/0000-0002-0952-8325
Haiping RenJiangxi University of Science and Technology, Nanchang, China.ORCID https://orcid.org/0000-0002-2460-2845
Wenbing ZhaoDepartment of Electrical Engineering and Computer Science, Cleveland State University, Cleveland, OH 44115, USA.
Yonghong PengFaculty of Computer Science, University of Sunderland, Sunderland, UK.ORCID https://orcid.org/0000-0002-5508-1819
Yutian XiaoSchool of Informatics, Xiamen University, Xiamen, China.
Yiwen LuDepartment of Computer Science, Tongji University, Shanghai, China.
Yongshuo ZongDepartment of Computer Science, Tongji University, Shanghai, China.
Yimin DingCollege of Electronics and Information Engineering, Tongji University, Shanghai, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Magnetic resonance (MR) images are often contaminated by Gaussian noise, an electronic noise caused by the random thermal motion of electronic components, which reduces the quality and reliability of the images. This paper puts forward a hybrid denoising algorithm for MR images based on two sparsely represented morphological components and one residual part. To begin with, decompose a noisy MR image into the cartoon, texture, and residual parts by MCA, and then each part is denoised by using Wiener filter, wavelet hard threshold, and wavelet soft threshold, respectively. Finally, stack up all the denoised subimages to obtain the denoised MR image. The experimental results show that the proposed method has significantly better performance in terms of mean square error and peak signal-to-noise ratio than each method alone.

Indexed as

AlgorithmsBrainComputational BiologyComputer SimulationDatabases, FactualHumansImage Interpretation, Computer-AssistedMagnetic Resonance ImagingNeuroimagingNormal DistributionPrincipal Component AnalysisSignal Processing, Computer-AssistedSignal-To-Noise RatioWavelet Analysis

Identifiers

PMID32411276
PMCPMC7152958

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.