Evidence map›Paper›PMID 32410287›Full record

ArticleTransfusion2020

Isoagglutinin reduction in intravenous immunoglobulin (IgPro10, Privigen) by specific immunoaffinity chromatography reduces its reporting rates of hemolytic reactions: an analysis of spontaneous adverse event reports.

Amgad Shebl, Susie Gabriel, Kristy Van Dinther, Alphonse Hubsch, John-Philip Lawo, Liane Hoefferer, Susan Welsh

Open access · hybridAbstract read
In one paragraph

Article in Transfusion, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.6field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 9 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 5 countries.

Amgad SheblCSL Behring GmbH, Marburg, Germany.ORCID 0000-0001-5376-4168
Susie GabrielCSL Limited, Parkville, Melbourne, Australia.
Kristy Van DintherCSL Limited, Parkville, Melbourne, Australia.
Alphonse HubschCSL Behring AG, Bern, Switzerland.
John-Philip LawoCSL Behring GmbH, Marburg, Germany.
Liane HoeffererCSL Behring AG, Bern, Switzerland.
Susan WelshCSL Behring, King of Prussia, Pennsylvania, USA.
Behringwerke (Germany) · DECSL (Switzerland) · CHCSL (United Kingdom) · GBCSL (United States) · US

Funding

CSL Behring
6 · The paper itself

Abstract

backgroundHemolysis is an infrequent but recognized and potentially serious adverse effect of intravenous immunoglobulin (IVIG). Relatively elevated hemolysis reporting rates were seen with some IVIG products with high anti-A/B isoagglutinin content, among which IgPro10 (Privigen, CSL Behring). For IgPro10, two isoagglutinin reduction measures were successively implemented: 1) anti-A donor screening and 2) immunoaffinity chromatography (IAC; Ig IsoLo)-based isoagglutinin reduction step included in the production process. The aim of this analysis was to investigate the effects of these isoagglutinin reduction measures on the reporting rates of IgPro10 hemolysis worldwide. STUDY DESIGN AND

methodsBetween February 2008 and December 2018, hemolysis reports from the CSL Behring Global Safety Database were analyzed in relationship to changes in IVIG IgPro10 production methods. Further analysis classified hemolysis reports by indication and blood group.

resultsMedian (minimum-maximum) anti-A/anti-B titers were 32 (8-64)/16 (8-32) at baseline, 32 (8-64)/16 (8-32) after donor screening, and 8 (8-32)/4 (2-8) after implementation of IAC. The reporting rate of hemolytic reactions per 1000 kg IgPro10 sold was 4.05 cases at baseline, 2.00 after donor screening, and 0.50 after implementation of IAC. In 2018, there were seven reports of hemolytic reactions; representing 0.18 cases per 1000 kg IgPro10 sold, with a reduction of 95.6% versus baseline.

conclusionFollowing implementation of the IAC isoagglutinin reduction step, spontaneous reports of hemolytic events with IgPro10 were significantly and consistently reduced versus IgPro10 without isoagglutinin reduction, offering patients a more favorable benefit-risk profile.

Indexed as

Chromatography, AffinityHemolysisABO Blood-Group SystemHemagglutininsHumansImmunoglobulins, IntravenousABO Blood-Group SystemHemagglutininsImmunoglobulins, Intravenous

Identifiers

PMID32410287
PMCPMC7383922
OpenAlexW3024852502

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.