Evidence map›Paper›PMID 32409999›Full record

SynthesisCardiovascular and interventional radiology2020

(In)comparability of Carotid Artery Stent Characteristics: A Systematic Review on Assessment and Comparison with Manufacturer Data.

Evelien E de Vries, Mert Kök, Astrid M Hoving, Cornelis H Slump, Raechel J Toorop, Gert J de Borst

Open access · hybridAbstract readSystematic Review
In one paragraph

Synthesis in Cardiovascular and interventional radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.8field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Evelien E de VriesDepartment of Vascular Surgery, University Medical Center Utrecht, Room G04.129, PO Box 85500, 3508 GA, Utrecht, The Netherlands.
Mert KökDepartment of Vascular Surgery, University Medical Center Utrecht, Room G04.129, PO Box 85500, 3508 GA, Utrecht, The Netherlands.
Astrid M HovingDepartment of Vascular Surgery, University Medical Center Utrecht, Room G04.129, PO Box 85500, 3508 GA, Utrecht, The Netherlands.
Cornelis H SlumpDepartment of Robotics and Mechatronics (EEMCS), University of Twente, PO Box 217, Enschede, The Netherlands.
Raechel J TooropDepartment of Vascular Surgery, University Medical Center Utrecht, Room G04.129, PO Box 85500, 3508 GA, Utrecht, The Netherlands.
Gert J de BorstDepartment of Vascular Surgery, University Medical Center Utrecht, Room G04.129, PO Box 85500, 3508 GA, Utrecht, The Netherlands. G.J.deBorst-2@umcutrecht.nl.
Utrecht University · NLUniversity of Twente · NLUniversity Medical Center Utrecht · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeCarotid stent (CS) characteristics, such as radial force, scaffolding and flexibility, are continuously modified by stent manufacturers aiming to improve stent performance. Since manufacturers' definitions and assessment methods are not disclosed, it is unknown how characteristics of different CSs relate to each other or to published literature. We examined in vitro methodological techniques used to measure CS characteristics and assessed comparability between published papers and outcomes as provided by the manufacturers.

methodsA systematic review was conducted in MEDLINE, Embase, Cochrane, and Scopus databases. Studies reporting on in vitro investigations of predefined characteristics of CS used in current everyday clinical practice were included. The predefined characteristics were radial force, scaffolding, flexibility, foreshortening, side-branch preservation and visibility. Eight manufacturers of 10 currently used CS were contacted and data on the predefined device characteristics was requested.

results12 published articles were included and six stent manufacturers provided data on six stents (two refused to share data). Used methodologies to measure stent characteristics in published literature and manufacturer data varied greatly for all included characteristics except foreshortening. The number of different units of measurement to express outcomes ranged from two for foreshortening to six for radial force.

conclusionA variety of methodologies and outcome measures is used to quantify CS characteristics, which hampers comparisons between published studies and manufacturer data. Future studies are encouraged to synchronize methodologies and outcome measures. Manufacturers are encouraged up to increase transparency of applied testing methodologies and outcomes.

Indexed as

Prosthesis DesignStentsTechnology Assessment, BiomedicalCarotid ArteriesCarotid StenosisCommerceHumansIn Vitro TechniquesTreatment OutcomeCarotid artery stentCarotid stenosisIn vitro testingMechanical behaviorSystematic review

Identifiers

PMID32409999
PMCPMC7524852
OpenAlexW3024521840

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.