Evidence map›Paper›PMID 32408276›Full record

ArticlePhysics in medicine and biology2020

Scatter imaging during lung stereotactic body radiation therapy characterized with phantom studies.

Kevin C Jones, Julius Turian, Gage Redler, Gizem Cifter, John Strologas, Alistair Templeton, Damian Bernard, James C H Chu

Open access · bronzeAbstract read
In one paragraph

Article in Physics in medicine and biology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Kevin C JonesDepartment of Radiation Oncology, Rush University Medical Center, Chicago, IL, United States of America.ORCID 0000-0002-8530-1931
Julius TurianDepartment of Radiation Oncology, Rush University Medical Center, Chicago, IL, United States of America.ORCID 0000-0001-5121-9094
Gage RedlerDepartment of Radiation Oncology, Moffitt Cancer Center, Tampa, FL, United States of America.
Gizem CifterDepartment of Radiation Oncology, George Washington University Hospital, Washington DC, United States of America.
John StrologasDepartment of Physics, University of Ioannina, Ioannina, Greece.ORCID 0000-0002-2225-7160
Alistair TempletonDepartment of Radiation Oncology, Rush University Medical Center, Chicago, IL, United States of America.
Damian BernardDepartment of Radiation Oncology, Rush University Medical Center, Chicago, IL, United States of America.
James C H ChuDepartment of Radiation Oncology, Rush University Medical Center, Chicago, IL, United States of America.
Rush University Medical Center · USGeorge Washington University Hospital · USMoffitt Cancer Center · USUniversity of Ioannina · GR

Funding

Scatter imaging for stereotactic ablative radiation therapy of lung cancerR21CA213407 · NCI · RUSH UNIVERSITY MEDICAL CENTER · PI CHU, JAMES C.H. · 2017 to 2018
$347k
NCI NIH HHS R21 CA213407
6 · The paper itself

Abstract

By collecting photons scattered out of the therapy beam, scatter imaging creates images of the treated volume. Two phantoms were used to assess the possible application of scatter imaging for markerless tracking of lung tumors during stereotactic body radiation therapy (SBRT) treatment. A scatter-imaging camera was assembled with a CsI flat-panel detector and a 5 mm diameter pinhole collimator. Scatter images were collected during the irradiation of phantoms with megavoltage photons. To assess scatter image quality, spherical phantom lung tumors of 2.1-2.8 cm diameters were placed inside a static, anthropomorphic phantom. To show the efficacy of the technique with a moving target (3 cm diameter), the position of a simulated tumor was tracked in scatter images during sinusoidal motion (15 mm amplitude, 0.25 Hz frequency) in a dynamic lung phantom in open-field, dynamic conformal arc (DCA), and volumetric modulated arc therapy (VMAT) deliveries. Anatomical features are identifiable on static phantom scatter images collected with 10 MU of delivered dose (2.1 cm diameter lung tumor contrast-to-noise ratio of 4.4). The contrast-to-noise ratio increases with tumor size and delivered dose. During dynamic motion, the position of the 3.0 cm diameter lung tumor was identified with a root-mean-square error of 0.8, 1.2, and 2.9 mm for open field (0.3 s frame integration), DCA (0.5 s), and VMAT (0.5 s), respectively. Based on phantom studies, scatter imaging is a potential technique for markerless lung tumor tracking during SBRT without additional imaging dose. Quality scatter images may be collected at low, clinically relevant doses (10 MU). Scatter images are capable of sub-millimeter tracking precision, but modulation decreases accuracy.

Indexed as

Phantoms, ImagingScattering, RadiationHumansLung NeoplasmsMolecular ImagingRadiosurgeryRadiotherapy, Intensity-Modulated

Identifiers

PMID32408276
PMCPMC8341471
OpenAlexW3025023005

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.