ArticleSensors (Basel, Switzerland)2020
Development of Novel Real-Time Radiation Systems Using 4-Channel Sensors.
Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
22 citing papers in PubMed.
- Development and validation of a pregnant phantom with adjustable fetal presentation for region-specific fetal radiation dose assessment during pelvic radiography.Journal of applied clinical medical physics · 2026Article
- Transition from a detector-dose-based to a CNR-based cerebral angiography system: evaluation of image quality and radiation dose.Radiological physics and technology · 2026Article
- Fundamental evaluation of a novel upright shield to protect medical personnel from scattered radiation during endoscopic retrograde cholangiopancreatography using a C-arm system.Journal of radiation research · 2026Article
- Article
- Real time eye dose reduction in fluoroscopy with auditory and visual feedback dosimeter through swine model experiments.Scientific reports · 2024Article
- Basic Performance Evaluation of a Radiation Survey Meter That Uses a Plastic-Scintillation Sensor.Sensors (Basel, Switzerland) · 2024Article
- Eye Lens Radiation Dose to Nurses during Cardiac Interventional Radiology: An Initial Study.Diagnostics (Basel, Switzerland) · 2023Article
- Spatial Scattering Radiation to the Radiological Technologist during Medical Mobile Radiography.Bioengineering (Basel, Switzerland) · 2023Article
- Evaluation of radiation dose for inferior vena cava filter placement during pregnancy: A comparison of dosimetry and dose calculation software.Journal of applied clinical medical physics · 2023Article
- Evaluation of a New Real-Time Dosimeter Sensor for Interventional Radiology Staff.Sensors (Basel, Switzerland) · 2023Article
- Article
- Chemosensing Properties of Coumarin Derivatives: Promising Agents with Diverse Pharmacological Properties, Docking and DFT Investigation.Molecules (Basel, Switzerland) · 2022Article
- Development of a New Radiation Shield for the Face and Neck of IVR Physicians.Bioengineering (Basel, Switzerland) · 2022Article
- What are useful methods to reduce occupational radiation exposure among radiological medical workers, especially for interventional radiology personnel?Radiological physics and technology · 2022Review
- Lens dose reduction with a bismuth shield in neuro cone-beam computed tomography: an investigation on optimum shield device placement conditions.Radiological physics and technology · 2022Article
- Occupational eye dose correlation with neck dose and patient-related quantities in interventional cardiology procedures.Radiological physics and technology · 2022Article
- Radiation Eye Dose for Physicians in CT Fluoroscopy-Guided Biopsy.Tomography (Ann Arbor, Mich.) · 2022Article
- Development, Characterization and Valuable Use of Novel Dosimeter Film Based on PVA Polymer Doped Nitro Blue Tetrazolium Dye and AgNOPolymers · 2021Article
- Non-Lead Protective Aprons for the Protection of Interventional Radiology Physicians from Radiation Exposure in Clinical Settings: An Initial Study.Diagnostics (Basel, Switzerland) · 2021Article
- An 8.72 µW Low-Noise and Wide Bandwidth FEE Design for High-Throughput Pixel-Strip (PS) Sensors.Sensors (Basel, Switzerland) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Radiation-related tissue injuries after medical radiation procedures, such as fluoroscopically guided intervention (FGI), have been reported in patients. Real-time monitoring of medical radiation exposure administered to patients during FGI is important to avoid such tissue injuries. In our previous study, we reported a novel (prototype) real-time radiation system for FGI. However, the prototype sensor indicated low sensitivity to radiation exposure from the side and back, although it had high-quality fundamental characteristics. Therefore, we developed a novel 4-channel sensor with modified shape and size than the previous sensor, and evaluated the basic performance (i.e., measured the energy, dose linearity, dose rate, and angular dependence) of the novel and previous sensors. Both sensors of our real-time dosimeter system demonstrated the low energy dependence, excellent dose linearity (R
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.