ArticleJournal of healthcare engineering2020
A Phlegm Stagnation Monitoring Based on VDS Algorithm.
Article in Journal of healthcare engineering, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In the nonmedical sputum monitoring system, a practical solution for phlegm stagnation care of patients was proposed. Through the camera, the video images of patients' laryngeal area were obtained in real time. After processing and analysis on these video frame images, the throat movement area was found out. A three-frame differential method was used to detect the throat moving targets. Anomalies were identified according to the information of moving targets and the proposed algorithm. Warning on the abnormal situation can help nursing personnel to deal with sputum blocking problem more effectively. To monitor the patients' situation in real time, this paper proposed a VDS algorithm, which extracted the speed characteristics of moving objects and combined with the DTW algorithm and SVM algorithm for sequence image classification. Phlegm stagnation symptoms of patients were identified timely for further medical care. In order to evaluate the effectiveness, our method was compared with the DTW, SVM, CTM, and HMM methods. The experimental results showed that this method had a higher recognition rate and was more practical in a nonmedical monitoring system.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.