ArticleESC heart failure2020
Contemporary use of devices in chronic heart failure in the Netherlands.
Article in ESC heart failure, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 9 citations in OpenAlex.
- Effects of levothyroxine in subclinical hypothyroidism and heart failure with reduced ejection fraction: An open-label randomized trial.Cell reports. Medicine · 2024Trial
- Awareness, Diagnostic Approaches, and Management of Heart Failure in Korea: A Nationwide Survey Comparing Primary Care Physicians and Cardiology Specialists.International journal of heart failure · 2026Article
- Personalized Heart Failure Management: Bridging Technology and Care.Journal of the American Heart Association · 2024Article
- Integration of a Smartphone HF-Dedicated App in the Remote Monitoring of Heart Failure Patients with Cardiac Implantable Electronic Devices: Patient Access, Acceptance, and Adherence to Use.Journal of clinical medicine · 2023Article
- Clinical profile and 90 day outcomes of 10 851 heart failure patients across India: National Heart Failure Registry.ESC heart failure · 2022Article
- Utilization and Efficacy of Cardiac Resynchronization Therapy in Patients With Chronic Heart Failure - A Report From the CHART-2 Study.Circulation reports · 2022Article
- Variation in regional implantation patterns of cardiac implantable electronic device in Switzerland.PloS one · 2022Article
- Heart failure treatment in patients with cardiac implantable electronic devices: Opportunity for improvement.Heart rhythm O2 · 2021Article
- Contemporary use of devices in chronic heart failure in the Netherlands.ESC heart failure · 2020Article
- Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 9 institutions in 2 countries.
Funding
Abstract
aimsDespite previous surveys regarding device implantation rates in heart failure (HF), insight into the real-world management with devices is scarce. Therefore, we investigated device implantation rates in HF with reduced left ventricular ejection fraction (LVEF) in 34 Dutch centres. METHODS AND
resultsA cross-sectional outpatient registry was conducted in 6666 patients with LVEF < 50% and with information about device implantation available [74 (66-81) years of age; 64% male]. Patients were classified into conventional pacemakers (PM, n = 562), implantable cardioverter defibrillators (ICD, n = 1165), and cardiac resynchronization therapy with defibrillator function (CRT-D, n = 885) or pacemaker function only (CRT-P, n = 248), or no device (n = 3806). Centres were divided into ICD-implanting and CRT-implanting and referral centres. Overall, 17.5% had an ICD, 13.3% CRT-D, 3.7% CRT-P, and 8.4% PM. Of those with LVEF ≤ 30%, 42.5% had ICD or CRT-D therapy. A large variation in implantation rates existed between centres: 3-51% for ICD therapy, 0.3-44% for CRT-D therapy, 0-11% for CRT-P therapy, and 0-25% PM therapy. Implantation centres showed higher implantation rates of ICD, CRT-D, and CRT-P compared with referral centres [36% vs. 25% for defibrillators (ICD or CRT-D) and 17% vs. 9% for CRT devices (CRT-D or CRT-P), respectively, P < 0.001], independently of other factors. A large number of clinical factors were predictive for device usage. Among other, LVEF < 40% and male sex were independent positive predictors for ICD/CRT-D use [odds ratio (OR) = 3.33, P < 0.001; OR = 1.87, P = 0.019, respectively]. Older age was independently associated with less ICD/CRT-D (OR = 0.96 per year, P < 0.001) and more CRT-P/PM use (OR = 1.03 per year, P = 0.006).
conclusionsIn this large Dutch HF registry, less than half of the patients with reduced LVEF received an ICD or CRT, even if LVEF was ≤30%, and a large variation between centres existed. Patients from implantation centres had more often ICD or CRT. More uniformity regarding guideline-based use of device therapy in clinical practice is needed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.