Evidence map›Paper›PMID 32393346›Full record

ReviewJournal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale2020

Aerosol-generating otolaryngology procedures and the need for enhanced PPE during the COVID-19 pandemic: a literature review.

Paul Mick, Russell Murphy

Open access · goldAbstract readReview
In one paragraph

Review in Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 109 papers, 7 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
109citing papers in PubMed, 7 pooled it
26.6field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

109 citing papers in PubMed, 7 syntheses or guidelines pooled it, 227 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. CSO (Canadian Society of Otolaryngology - Head & Neck Surgery) position paper on rhinologic and skull base surgery during the COVID-19 pandemic.Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale · 2020
    Guideline
  4. Guideline
  5. Pooled it
  6. Guideline
  7. Guideline
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Telemedicine and Otolaryngology in the COVID-19 Era.The Annals of otology, rhinology, and laryngology · 2023
    Article
  16. Review
  17. Article
  18. Facial Trauma During the COVID-19 Pandemic.Craniomaxillofacial trauma & reconstruction · 2022
    Article
  19. Article
  20. Respiratory Particle Emission During Voice Assessment and Therapy Tasks in a Single Subject.Journal of voice : official journal of the Voice Foundation · 2022
    Article

49 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Paul MickDepartment of Surgery, University of Saskatchewan, 2708-103 Hospital Drive, Saskatoon, SK, S7N 0W8, Canada. ptmick@gmail.com.ORCID http://orcid.org/0000-0002-9841-3000
Russell MurphyDepartment of Surgery, University of Saskatchewan, Wall Street ENT Clinic, 230-140 Wall Street, Saskatoon, SK, S7K 1N4, Canada.
University of Saskatchewan · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAdequate personal protective equipment is needed to reduce the rate of transmission of COVID-19 to health care workers. Otolaryngology groups are recommending a higher level of personal protective equipment for aerosol-generating procedures than public health agencies. The objective of the review was to provide evidence that a.) demonstrates which otolaryngology procedures are aerosol-generating, and that b.) clarifies whether the higher level of PPE advocated by otolaryngology groups is justified. MAIN BODY: Health care workers in China who performed tracheotomy during the SARS-CoV-1 epidemic had 4.15 times greater odds of contracting the virus than controls who did not perform tracheotomy (95% CI 2.75-7.54). No other studies provide direct epidemiological evidence of increased aerosolized transmission of viruses during otolaryngology procedures. Experimental evidence has shown that electrocautery, advanced energy devices, open suctioning, and drilling can create aerosolized biological particles. The viral load of COVID-19 is highest in the upper aerodigestive tract, increasing the likelihood that aerosols generated during procedures of the upper aerodigestive tract of infected patients would carry viral material. Cough and normal breathing create aerosols which may increase the risk of transmission during outpatient procedures. A significant proportion of individuals infected with COVID-19 may not have symptoms, raising the likelihood of transmission of the disease to inadequately protected health care workers from patients who do not have probable or confirmed infection. Powered air purifying respirators, if used properly, provide a greater level of filtration than N95 masks and thus may reduce the risk of transmission.

conclusionDirect and indirect evidence suggests that a large number of otolaryngology-head and neck surgery procedures are aerosol generating. Otolaryngologists are likely at high risk of contracting COVID-19 during aerosol generating procedures because they are likely exposed to high viral loads in patients infected with the virus. Based on the precautionary principle, even though the evidence is not definitive, adopting enhanced personal protective equipment protocols is reasonable based on the evidence. Further research is needed to clarify the risk associated with performing various procedures during the COVID-19 pandemic, and the degree to which various personal protective equipment reduces the risk.

Indexed as

AerosolsBetacoronavirusCoronavirus InfectionsCOVID-19HumansInfection ControlInfectious Disease Transmission, Patient-to-ProfessionalOtorhinolaryngologic Surgical ProceduresPandemicsPersonal Protective EquipmentPneumonia, ViralRespiratory SystemSARS-CoV-2Viral LoadAerosolsAerosol generating medical procedureAGMPCOVID-19ENTOtolaryngologyOtolaryngology-head and neck surgeryPersonal protective equipmentPPE

Identifiers

PMID32393346
PMCPMC7212733
OpenAlexW3023003554

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.