Evidence map›Paper›PMID 32392901›Full record

ArticleNanomaterials (Basel, Switzerland)2020

Internalization and Viability Studies of Suspended Nanowire Silicon Chips in HeLa Cells.

Sara Durán, Marta Duch, Rodrigo Gómez-Martínez, Marta Fernández-Regúlez, Juan Pablo Agusil, Manuel Reina, Claudia Müller, Álvaro San Paulo, Jaume Esteve, Susana Castel and 1 more

Abstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Sara DuránInstituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus UAB, Cerdanyola, 08193 Barcelona, Spain.
Marta DuchInstituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus UAB, Cerdanyola, 08193 Barcelona, Spain.
Rodrigo Gómez-MartínezInstituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus UAB, Cerdanyola, 08193 Barcelona, Spain.
Marta Fernández-RegúlezInstituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus UAB, Cerdanyola, 08193 Barcelona, Spain.
Juan Pablo AgusilInstituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus UAB, Cerdanyola, 08193 Barcelona, Spain.
Manuel ReinaDepartamento de Biología Celular, Fisiología e Inmunología, Facultad de Biología, Universitat de Barcelona, 08028 Barcelona, Spain.
Claudia MüllerDepartamento de Biología Celular, Fisiología e Inmunología, Facultad de Biología, Universitat de Barcelona, 08028 Barcelona, Spain.
Álvaro San PauloInstituto de Microelectrónica de Madrid, IMM-CNM (CSIC), Isaac Newton 8, Tres Cantos, 28760 Madrid, Spain.
Jaume EsteveInstituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus UAB, Cerdanyola, 08193 Barcelona, Spain.
Susana CastelDepartamento de Biología Celular, Fisiología e Inmunología, Facultad de Biología, Universitat de Barcelona, 08028 Barcelona, Spain.
José A PlazaInstituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus UAB, Cerdanyola, 08193 Barcelona, Spain.

Funding

Spanish Goverment TEC2017-85059-c3
6 · The paper itself

Abstract

Micrometer-sized silicon chips have been demonstrated to be cell-internalizable, offering the possibility of introducing in cells even smaller nanoelements for intracellular applications. On the other hand, silicon nanowires on extracellular devices have been widely studied as biosensors or drug delivery systems. Here, we propose the integration of silicon nanowires on cell-internalizable chips in order to combine the functional features of both approaches for advanced intracellular applications. As an initial fundamental study, the cellular uptake in HeLa cells of silicon 3 µm × 3 µm nanowire-based chips with two different morphologies was investigated, and the results were compared with those of non-nanostructured silicon chips. Chip internalization without affecting cell viability was achieved in all cases; however, important cell behavior differences were observed. In particular, the first stage of cell internalization was favored by silicon nanowire interfaces with respect to bulk silicon. In addition, chips were found inside membrane vesicles, and some nanowires seemed to penetrate the cytosol, which opens the door to the development of silicon nanowire chips as future intracellular sensors and drug delivery systems.

Indexed as

biomimeticscellsmicroparticlesmicrotechnologynanowiressilicon

Identifiers

PMID32392901
PMCPMC7279308

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.