Evidence map›Paper›PMID 32388941›Full record

ArticleJournal of neurogastroenterology and motility2020

Esophageal Baseline Impedance From High-resolution Impedance Manometry Correlates With Mean Nocturnal Baseline Impedance From pH-impedance Monitoring.

Anthony Horton, Brian Sullivan, Katie Charles, Thasha McIntosh, Andrea Davis, Ziad Gellad, Rahul Shimpi, C Prakash Gyawali, Amit Patel

Abstract read
In one paragraph

Article in Journal of neurogastroenterology and motility, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Anthony HortonDivision of Gastroenterology, Duke University School of Medicine, Durham, NC, USA.ORCID 0000-0002-6571-9927
Brian SullivanDivision of Gastroenterology, Duke University School of Medicine, Durham, NC, USA.
Katie CharlesDivision of Gastroenterology, Duke University School of Medicine, Durham, NC, USA.
Thasha McIntoshDurham Veterans Affairs Medical Center, Durham, NC, USA.
Andrea DavisDurham Veterans Affairs Medical Center, Durham, NC, USA.
Ziad GelladDivision of Gastroenterology, Duke University School of Medicine, Durham, NC, USA.
Rahul ShimpiDivision of Gastroenterology, Duke University School of Medicine, Durham, NC, USA.
C Prakash GyawaliDivision of Gastroenterology, Washington University School of Medicine, St Louis, MO, USA.
Amit PatelDivision of Gastroenterology, Duke University School of Medicine, Durham, NC, USA.ORCID 0000-0001-7214-5901

Funding

Simulation-Guided Systems Redesign in GI EndoscopyIK2HX001555 · VA · DURHAM VA MEDICAL CENTER · PI GELLAD, ZIAD · 2015 to 2019
–
HSRD VA IK2 HX001555
6 · The paper itself

Abstract

Background/Aims: Esophageal baseline impedance (BI) can be extracted from pH-impedance tracings as mean nocturnal baseline impedance (MNBI), and from high-resolution impedance manometry (HRIM), but it is unknown if values are similar between acquisition methods across HRIM manufacturers. We aim to assess correlations between MNBI and BI from HRIM (BI-HRIM) from 2 HRIM manufacturers in the setting of physiologic acid exposure time (AET). Methods: HRIM and pH-impedance monitoring demonstrating physiologic AET (< 4%) off proton pump inhibitors were required. BI-HRIM was extracted as the average from 5 cm and 10 cm above the lower esophageal sphincter. Distal BI-HRIM (DBI-HRIM) was also extracted from the most distal channel (Medtronic studies). MNBI was extracted from 6 channels. Concordance between BI-HRIM across manufacturers with MNBI was analyzed. Results: Thirty-six patients met the inclusion criteria (59.6 ± 1.7 years; 22% female; body mass index 30.5 ± 0.7; AET 1.6 ± 0.2%). Although MNBI was similar at all channels ( Conclusions: While numeric differences exist between manufacturers, BI-HRIM correlates with MNBI from corresponding channels in patients with physiologic AET. Comparison with AET elevation is needed to determine correlations between pathologic MNBI with BI-HRIM across manufacturers. The optimal HRIM channels from which BI values should be extracted also warrants further study.

Indexed as

Electric impedanceEsophageal mucosaEsophageal pH monitoringGastroesophageal reflux

Identifiers

PMID32388941
PMCPMC7547185

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.