ArticleIEEE transactions on medical imaging2020
Phantom Studies of Fused-Data TREIT Using Only Biopsy-Probe Electrodes.
Article in IEEE transactions on medical imaging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 4 citations in OpenAlex.
- Ex-Vivo Prostate Evaluation of Fused-Data TREIT Using Only Biopsy-Probe Electrodes.IEEE transactions on bio-medical engineering · 2026Article
- Novel Electrode Placement in Electrical Bioimpedance-Based Stroke Detection: Effects on Current Penetration and Injury Characterization in a Finite Element Model.IEEE transactions on bio-medical engineering · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
Abstract
Transrectal electrical impedance tomography (TREIT) is a novel imaging modality being developed for prostate biopsy guidance and cancer characterization. We describe a novel fused-data TREIT (fd-TREIT) system and approach developed to improve imaging robustness and evaluate it on challenging clinically-representative phantoms. The new approach incorporates 8 electrodes (in 2 rows) on a biopsy probe (BP) and 12 electrodes on the face of a transrectal ultrasound (TRUS) probe and includes a biopsy gun, instrument tracking, 3D-printed needle guide, and EIT hardware and software. The approach was evaluated via simulation, a series of prostate-shaped gel phantoms, and an ex vivo bovine tissue sample using only absolute reconstructions. The simulations surprisingly found that using only biopsy-probe electrode measurements, i.e. omitting TRUS-probe electrode measurements, significantly improves robustness to noise thus leading to simpler modeling and significant decreases in computational times (~13x speed-up/reconstructions in ~27 minutes). The gel phantom experiments resulted in reconstructions with area under the curve (AUC) values extracted from receiver operator characteristic curves of >0.85 for 4 out of the 5 tests, and when incorporating inclusion boundaries resulted in absolute reconstructions yielding 1.9% and 12.2% average percent errors for 3 consistent tests and all 5 tests, respectively. Ex vivo bovine tests revealed qualitatively that the fd-TREIT approach can largely discriminate a complex adipose and muscle interface in a realistic setting using data from 9 biopsy probe states (biopsy core locations). The algorithms developed here on challenging phantoms suggest strong promise for this technology to aid in imaging during routine 12-core biopsies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.