ArticleCardiovascular and interventional radiology2020
Acute Thrombus Burden on Coated Flow Diverters Assessed by High Frequency Optical Coherence Tomography.
Article in Cardiovascular and interventional radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 12 citations in OpenAlex.
- Flow diverter surface modifications for aneurysm treatment: A review of the mechanisms and data behind existing technologies.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Review
- Development of a Brain Catheter for Optical Coherence Tomography in Advanced Cerebrovascular Diagnostics.Biosensors · 2025Article
- Volumetric microscopy of cerebral arteries with a miniaturized optical coherence tomography imaging probe.Science translational medicine · 2024Article
- The FRESH Study: Treatment of Intracranial Aneurysms with the New FRED X Flow Diverter with Antithrombotic Surface Treatment Technology-First Multicenter Experience in 161 Patients.AJNR. American journal of neuroradiology · 2023Article
- Hydrophilic Surface Coating of Flow Diverters: A Possible Way to Omit Dual Platelet Aggregation Inhibition.Cardiovascular and interventional radiology · 2020Article
- Pilot feasibility study of intraprocedural transcranial Doppler monitoring to assess Heal coating thrombogenicity in flow diversion.Frontiers in neurologyArticle
Corrections and comments
- Commented on by
Authors and funding
7 authors at 3 institutions in 2 countries.
Funding
Abstract
purposeThe implantation of flow diverters requires administration of dual anti-platelet therapy, posing the potential for complications. The p48MW HPC (phenox, Bochüm, Germany) hydrophilic-coated flow diverting stent is designed to be anti-thrombotic, thus opening the potential for single anti-platelet therapy. We deploy a novel intravascular high-resolution imaging technique, high-frequency optical coherence tomography (HF-OCT), to study in an animal model the acute thrombus formation on coated p48MW devices versus uncoated control devices.
methodsThree pigs were implanted with 4 flow diverters each, two test hydrophilic-coated devices, and two control uncoated devices (p48MW). Each pig was treated with a different anti-platelet regime: no anti-platelet therapy, aspirin only, aspirin and clopidogrel. Twenty minutes after the flow diverter was implanted, an HF-OCT data set was acquired. Acute clot formed on the flow diverter at each covered side branch was measured from the HF-OCT slices. Factors considered to be important were the device type (pHPC versus bare metal), aspirin, clopidogrel, and vessel location. A linear model was constructed from the significant factors.
resultsBoth coating (p < 0.001) and aspirin (p = 0.003) were significantly related to reduction in clot burden, leading to an approximate 100-fold and 50-fold reduction in clot, respectively.
conclusionsThis study shows the power of HF-OCT not only in the detection of clot but also the quantification of clot burden. In an animal model, the pHPC-coated p48MW significantly reduced acute thrombus formation over jailed side branches as compared to the bare metal p48MW that was nearly eliminated when combined with aspirin administration.