Evidence map›Paper›PMID 32384631›Full record

ArticleSensors (Basel, Switzerland)2020

Ultrasensitive and Highly Selective Graphene-Based Field-Effect Transistor Biosensor for Anti-Diuretic Hormone Detection.

Reena Sri Selvarajan, Ruslinda A Rahim, Burhanuddin Yeop Majlis, Subash C B Gopinath, Azrul Azlan Hamzah

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 37 citations in OpenAlex.

  1. Article
  2. Recent Advances in Xenes Based FET for Biosensing Applications.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Review
  3. Review
  4. Synthesis and Characterization of SiONanomaterials (Basel, Switzerland) · 2024
    Article
  5. Review
  6. Article
  7. Review
  8. Review
  9. Article
  10. Review
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Reena Sri SelvarajanInstitute of Microengineering and Nanoelectronics (IMEN), National University of Malaysia (UKM), Bangi 43600, Malaysia.
Ruslinda A RahimInstitute of Nanoelectronic Engineering (INEE), University Malaysia Perlis (UniMAP), Kangar 01000, Perlis, Malaysia.
Burhanuddin Yeop MajlisInstitute of Microengineering and Nanoelectronics (IMEN), National University of Malaysia (UKM), Bangi 43600, Malaysia.
Subash C B GopinathInstitute of Nanoelectronic Engineering (INEE), University Malaysia Perlis (UniMAP), Kangar 01000, Perlis, Malaysia.
Azrul Azlan HamzahInstitute of Microengineering and Nanoelectronics (IMEN), National University of Malaysia (UKM), Bangi 43600, Malaysia.ORCID 0000-0001-8916-4420
National University of Malaysia · MYUniversiti Malaysia Perlis · MY

Funding

Ministry of Higher Education (MOHE) Malaysia. AKU-95 HICoE MEMS for Artificial Kidney
6 · The paper itself

Abstract

Nephrogenic diabetes insipidus (NDI), which can be congenital or acquired, results from the failure of the kidney to respond to the anti-diuretic hormone (ADH). This will lead to excessive water loss from the body in the form of urine. The kidney, therefore, has a crucial role in maintaining water balance and it is vital to restore this function in an artificial kidney. Herein, an ultrasensitive and highly selective aptameric graphene-based field-effect transistor (GFET) sensor for ADH detection was developed by directly immobilizing ADH-specific aptamer on a surface-modified suspended graphene channel. This direct immobilization of aptamer on the graphene surface is an attempt to mimic the functionality of collecting tube V 2 receptors in the ADH biosensor. This aptamer was then used as a probe to capture ADH peptide at the sensing area which leads to changes in the concentration of charge carriers in the graphene channel. The biosensor shows a significant increment in the relative change of current ratio from 5.76 to 22.60 with the increase of ADH concentration ranging from 10 ag/mL to 1 pg/mL. The ADH biosensor thus exhibits a sensitivity of 50.00 µA· ( g / mL ) - 1 with a limit of detection as low as 3.55 ag/mL. In specificity analysis, the ADH biosensor demonstrated a higher current value which is 338.64 µA for ADH-spiked in phosphate-buffered saline (PBS) and 557.89 µA for ADH-spiked in human serum in comparison with other biomolecules tested. This experimental evidence shows that the ADH biosensor is ultrasensitive and highly selective towards ADH in PBS buffer and ADH-spiked in human serum.

Indexed as

Biosensing TechniquesGraphiteVasopressinsHormonesHumansTransistors, ElectronicGraphiteHormonesVasopressinsADH-specific aptameranti-diuretic hormoneartificial kidneydrain currentgraphene FET

Identifiers

PMID32384631
PMCPMC7248865
OpenAlexW3021361837

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.