Evidence map›Paper›PMID 32383353›Full record

ArticleOrthopaedic surgery2020

3D Finite Element Analysis of the Modular Prosthesis with Tooth Mechanism of the Femoral Shaft.

Jian-Feng Zhang, Yong-Cheng Hu, Bao-Cang Wang, Lei Wang, Hui Wang, Yong Li, Ming Yan, Hong-Tao Liu

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Jian-Feng ZhangDepartment of Osteopathy, The Second Hospital of Tangshan, Tangshan, China.ORCID https://orcid.org/0000-0002-6806-6546
Yong-Cheng HuDepartment of Orthopaedic Oncology, Tianjin Hospital, Tianjin, China.
Bao-Cang WangDepartment of Osteopathy, The Second Hospital of Tangshan, Tangshan, China.
Lei WangDepartment of Trauma Surgery, The Second Hospital of Tangshan, Tangshan, China.ORCID https://orcid.org/0000-0003-1755-6091
Hui WangDepartment of Osteopathy, The Second Hospital of Tangshan, Tangshan, China.
Yong LiDepartment of Osteopathy, The Second Hospital of Tangshan, Tangshan, China.
Ming YanDepartment of Osteopathy, The Second Hospital of Tangshan, Tangshan, China.
Hong-Tao LiuDepartment of Osteopathy, The Second Hospital of Tangshan, Tangshan, China.
Second Hospital of Tangshan · CNTianjin Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo evaluate the mechanical properties and provide a theoretical basis of a diaphyseal prosthesis with tooth mechanism using the finite element analysis method from the point of view of biomechanics.

methodsA 3D digital femur model was generated based on a 28-year-old healthy man's femoral computed tomography (CT) data in Mimics 17.0 and the customized diaphyseal prostheses with/without tooth mechanism were designed in SolidWorks 2016. The 3D femur model after 8 cm osteotomy in the middle of its shaft and the prostheses with/without tooth mechanism was imported into Abaqus 2016 and the finite element analysis models were established. Three biomechanical tests (compression test, torsion test, and 3P-bending test) under broken load were simulated in FEA to evaluate the performance of the prostheses.

resultsThe stress distributions of the two prostheses were similar and the maximum von Mises stresses placed on them were very close in each test. The maximum von Mises stresses on the prosthesis with tooth mechanism were 31.55, 319.7, and 447.4 MPa, respectively, and those on the prosthesis without tooth mechanism were 26.26, 300.4, and 455.2 MPa, respectively, in the compression, torsion, and 3P-bending tests. The maximum von Mises stresses on them were far below the ultimate tensile strength or ultimate compressive strength of the titanium alloy.

conclusionsThe diaphyseal prosthesis with tooth mechanism is helpful to adjust the rotation of the long bone during operation. Compared with the conventional diaphyseal prosthesis (without tooth mechanism), the diaphyseal prosthesis with tooth mechanism also has a good biomechanical performance and does not increase the risk of prosthetic failure.

Indexed as

Prostheses and ImplantsAdultBiomechanical PhenomenaDiaphysesFemurFinite Element AnalysisHumansImaging, Three-DimensionalMaleOsteotomyProsthesis ImplantationStress, MechanicalBiomechanicsFemurFinite element analysisProstheses and implantsRotation

Identifiers

PMID32383353
PMCPMC7307257
OpenAlexW3023279911

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.