Evidence map›Paper›PMID 32383105›Full record

ArticleInternational journal of computer assisted radiology and surgery2020

Three-dimensional guidance including shape sensing of a stentgraft system for endovascular aneurysm repair.

Sonja Jäckle, Verónica García-Vázquez, Tim Eixmann, Florian Matysiak, Felix von Haxthausen, Malte Maria Sieren, Hinnerk Schulz-Hildebrandt, Gereon Hüttmann, Floris Ernst, Markus Kleemann and 1 more

Abstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. A Steerable and Electromagnetically Tracked Catheter: Navigation Performance Compared With Image Fusion in a Swine Model.Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2024
    Article
  3. Extending bioelectric navigation for displacement and direction detection.International journal of computer assisted radiology and surgery · 2023
    Article
  4. Article
  5. Article
  6. Three-Dimensional Holographic Guidance, Navigation, and Control (3D-GNC) for Endograft Positioning in Porcine Aorta: Feasibility Comparison With 2-Dimensional X-Ray Fluoroscopy.Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2021
    Article
  7. Three-dimensional guidance including shape sensing of a stentgraft system for endovascular aneurysm repair.International journal of computer assisted radiology and surgery · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Sonja JäckleFraunhofer MEVIS, Institute for Digital Medicine, Maria-Goeppert-Straße 3, 23562, Lübeck, Germany. sonja.jaeckle@mevis.fraunhofer.de.ORCID http://orcid.org/0000-0002-2908-299X
Verónica García-VázquezInstitute for Robotics and Cognitive Systems, Universität zu Lübeck, Ratzeburger Allee 160, 23562, Lübeck, Germany.ORCID http://orcid.org/0000-0002-8140-3527
Tim EixmannInstitute of Biomedical Optics, Universität zu Lübeck, Ratzeburger Allee 160, 23562, Lübeck, Germany.ORCID http://orcid.org/0000-0001-9311-790X
Florian MatysiakDivision of Vascular- and Endovascular Surgery, Department of Surgery, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, 23562, Lübeck, Germany.ORCID http://orcid.org/0000-0002-8049-9889
Felix von HaxthausenInstitute for Robotics and Cognitive Systems, Universität zu Lübeck, Ratzeburger Allee 160, 23562, Lübeck, Germany.ORCID http://orcid.org/0000-0001-9679-5693
Malte Maria SierenDepartment for Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, 23562, Lübeck, Germany.ORCID http://orcid.org/0000-0002-3669-2892
Hinnerk Schulz-HildebrandtInstitute of Biomedical Optics, Universität zu Lübeck, Ratzeburger Allee 160, 23562, Lübeck, Germany.ORCID http://orcid.org/0000-0003-4389-9151
Gereon HüttmannInstitute of Biomedical Optics, Universität zu Lübeck, Ratzeburger Allee 160, 23562, Lübeck, Germany.ORCID http://orcid.org/0000-0002-5051-3037
Floris ErnstInstitute for Robotics and Cognitive Systems, Universität zu Lübeck, Ratzeburger Allee 160, 23562, Lübeck, Germany.ORCID http://orcid.org/0000-0002-0474-6673
Markus KleemannDivision of Vascular- and Endovascular Surgery, Department of Surgery, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, 23562, Lübeck, Germany.ORCID http://orcid.org/0000-0002-0247-4643
Torben PätzFraunhofer MEVIS, Institute for Digital Medicine, Am Fallturm 1, 28359, Bremen, Germany.ORCID http://orcid.org/0000-0003-1071-1220

Funding

Bundesministerium für Bildung und Forschung 13GW0228
6 · The paper itself

Abstract

purposeDuring endovascular aneurysm repair (EVAR) procedures, medical instruments are guided with two-dimensional (2D) fluoroscopy and conventional digital subtraction angiography. However, this requires X-ray exposure and contrast agent is used, and the depth information is missing. To overcome these drawbacks, a three-dimensional (3D) guidance approach based on tracking systems is introduced and evaluated.

methodsA multicore fiber with fiber Bragg gratings for shape sensing and three electromagnetic (EM) sensors for locating the shape were integrated into a stentgraft system. A model for obtaining the located shape of the first 38 cm of the stentgraft system with two EM sensors is introduced and compared with a method based on three EM sensors. Both methods were evaluated with a vessel phantom containing a 3D-printed vessel made of silicone and agar-agar simulating the surrounding tissue.

resultsThe evaluation of the guidance methods resulted in average errors from 1.35 to 2.43 mm and maximum errors from 3.04 to 6.30 mm using three EM sensors, and average errors from 1.57 to 2.64 mm and maximum errors from 2.79 to 6.27 mm using two EM sensors. Moreover, the videos made from the continuous measurements showed that a real-time guidance is possible with both approaches.

conclusionThe results showed that an accurate real-time guidance with two and three EM sensors is possible and that two EM sensors are already sufficient. Thus, the introduced 3D guidance method is promising to use it as navigation tool in EVAR procedures. Future work will focus on developing a method with less EM sensors and a detailed latency evaluation of the guidance method.

Indexed as

Angiography, Digital SubtractionAortic AneurysmBlood Vessel Prosthesis ImplantationEndovascular ProceduresFluoroscopyHumansImaging, Three-DimensionalPhantoms, ImagingElectromagnetic tracking systemEndovascular aneurysm repairEndovascular navigationFiber Bragg gratingsShape sensingStentgraft system

Identifiers

PMID32383105
PMCPMC7303070

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.