Evidence map›Paper›PMID 32381781›Full record

ArticleJournal of synchrotron radiation2020

Validation study of small-angle X-ray scattering tensor tomography.

Manuel Guizar-Sicairos, Marios Georgiadis, Marianne Liebi

Open access · hybridAbstract readValidation Study
In one paragraph

Article in Journal of synchrotron radiation, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
4.4field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Small-angle scattering tensor tomography algorithm for robust reconstruction of complex textures.Acta crystallographica. Section A, Foundations and advances · 2023
    Article
  6. Article
  7. Hierarchical Structure and Properties of the Bone at Nano Level.Bioengineering (Basel, Switzerland) · 2022
    Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 3 countries.

Manuel Guizar-SicairosPaul Scherrer Institute (PSI), 5232 Villigen, Switzerland.ORCID 0000-0002-8293-3634
Marios GeorgiadisInstitute for Biomechanics, ETH Zurich, 8093 Zurich, Switzerland.ORCID 0000-0003-0733-4559
Marianne LiebiPaul Scherrer Institute (PSI), 5232 Villigen, Switzerland.ORCID 0000-0002-5403-0593
Paul Scherrer Institute · CHETH Zurich · CH

Funding

Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung P400PM_180773
6 · The paper itself

Abstract

Small-angle scattering tensor tomography (SASTT) is a recently developed technique able to tomographically reconstruct the 3D reciprocal space from voxels within a bulk volume. SASTT extends the concept of X-ray computed tomography, which typically reconstructs scalar values, by reconstructing a tensor per voxel, which represents the local nanostructure 3D organization. In this study, the nanostructure orientation in a human trabecular-bone sample obtained by SASTT was validated by sectioning the sample and using 3D scanning small-angle X-ray scattering (3D sSAXS) to measure and analyze the orientation from single voxels within each thin section. Besides the presence of cutting artefacts from the slicing process, the nanostructure orientations obtained with the two independent methods were in good agreement, as quantified with the absolute value of the dot product calculated between the nanostructure main orientations obtained in each voxel. The average dot product per voxel over the full sample containing over 10 000 voxels was 0.84, and in six slices, in which fewer cutting artefacts were observed, the dot product increased to 0.91. In addition, SAXS tensor tomography not only yields orientation information but can also reconstruct the full 3D reciprocal-space map. It is shown that the measured anisotropic scattering for individual voxels was reproduced from the SASTT reconstruction in each voxel of the 3D sample. The scattering curves along different 3D directions are validated with data from single voxels, demonstrating SASTT's potential for a separate analysis of nanostructure orientation and structural information from the angle-dependent intensity distribution.

Indexed as

AnisotropyHumansImaging, Three-DimensionalScattering, Small AngleSpineTomography, X-Ray ComputedX-Ray Diffractionnanostructure orientationsSAXStensor tomography

Identifiers

PMID32381781
PMCPMC7206543
OpenAlexW3017630925

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.