Evidence map›Paper›PMID 32376633›Full record

ArticleProceedings of the National Academy of Sciences of the United States of America2020

Sensitive magnetometry reveals inhomogeneities in charge storage and weak transient internal currents in Li-ion cells.

Yinan Hu, Geoffrey Z Iwata, Mohaddese Mohammadi, Emilia V Silletta, Arne Wickenbrock, John W Blanchard, Dmitry Budker, Alexej Jerschow

Abstract read
In one paragraph

Article in Proceedings of the National Academy of Sciences of the United States of America, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yinan HuInstitut für Physik, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany.
Geoffrey Z IwataInstitut für Physik, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany; iwata@uni-mainz.de alexej.jerschow@nyu.edu.ORCID 0000-0002-8435-5962
Mohaddese MohammadiDepartment of Chemistry, New York University, New York, NY 10003.
Emilia V SillettaDepartment of Chemistry, New York University, New York, NY 10003.ORCID 0000-0003-2856-2112
Arne WickenbrockInstitut für Physik, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany.
John W BlanchardHelmholtz Institute Mainz, GSI Helmholtzzentrum für Schwerionenforschung, 55099 Mainz, Germany.ORCID 0000-0002-1621-6637
Dmitry BudkerInstitut für Physik, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany.ORCID 0000-0002-7356-4814
Alexej JerschowDepartment of Chemistry, New York University, New York, NY 10003; iwata@uni-mainz.de alexej.jerschow@nyu.edu.ORCID 0000-0003-1521-9219

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The ever-increasing demand for high-capacity rechargeable batteries highlights the need for sensitive and accurate diagnostic technology for determining the state of a cell, for identifying and localizing defects, and for sensing capacity loss mechanisms. Here, we leverage atomic magnetometry to map the weak induced magnetic fields around Li-ion battery cells in a magnetically shielded environment. The ability to rapidly measure cells nondestructively allows testing even commercial cells in their actual operating conditions, as a function of state of charge. These measurements provide maps of the magnetic susceptibility of the cell, which follow trends characteristic for the battery materials under study upon discharge. In particular, hot spots of charge storage are identified. In addition, the measurements reveal the capability to measure transient internal current effects, at a level of μA, which are shown to be dependent upon the state of charge. These effects highlight noncontact battery characterization opportunities. The diagnostic power of this technique could be used for the assessment of cells in research, quality control, or during operation, and could help uncover details of charge storage and failure processes in cells.

Indexed as

battery diagnosticsmagnetic susceptibilitymagnetometryoptically pumped magnetometer

Identifiers

PMID32376633
PMCPMC7245122

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.