ArticlePloS one2020
Accurate HIV viral load measurement in primary health care settings using the cobas® plasma separation card.
Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 13 citations in OpenAlex.
- Performance of plasma separation cards for HIV drug-resistance genotyping in a resource-limited setting: comparison with plasma samples.The Journal of antimicrobial chemotherapy · 2026Article
- HCV RNA quantification using the Cobas Plasma Separation Card as an alternative to EDTA plasma: a prospective multicenter study.Scientific reports · 2026Article
- Brief Report: Undetectable HIV-1 Viral Load Among Virally Suppressed People Living With HIV: Implications for Undetectable Equals Untransmittable (U=U) in Resource-Limited Settings Using Dried Spot Testing.Journal of acquired immune deficiency syndromes (1999) · 2025Article
- Dried Blood Spots and Plasma Separation Cards can Broaden Access to Molecular Testing for HBV, HCV and HIV.Reviews in medical virology · 2025Review
- Quantitative Assessment of a Novel Device Designed for Patient-centric Sampling of Dried Plasma Using Targeted Proteomics.Analytical chemistry · 2025Article
- Article
- Acceptability and Feasibility of the Plasma Separation Card for an Integrated Model of Care for HBV and HCV Screening Among People Attending HIV Clinics in Cameroon and Uganda.Journal of epidemiology and global health · 2024Article
- Assessment of the performance of the plasma separation card for HIV-1 viral load monitoring in South Africa.Journal of clinical microbiology · 2024Article
- Viral load suppression among HIV-positive adult patients on the first-line antiretroviral treatment regimen in health facilities in the City of Ekurhuleni, Gauteng province, South Africa.The Pan African medical journal · 2024Article
- Direct Processing and Storage of Cell-Free Plasma Using Dried Plasma Spot Cards.ACS measurement science au · 2022Article
- Stability of HIV-1 Nucleic Acids in cobas Plasma Separation Card for Viral Load Measurement.American journal of clinical pathology · 2022Article
- Managing laboratory waste from HIV-related molecular testing: Lessons learned from African countries.Journal of hazardous materials letters · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 3 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionPlasma is considered the gold standard for HIV viral load (VL) testing, however its use is challenging due to the need for phlebotomy and centrifugation services, as well as cold chain for transporting to laboratories for testing. The use of Dried Blood Spot (DBS) specimen has allowed a rapid expansion of antiretroviral therapy (ART) monitoring in remote areas in many African countries, however, the VL in DBS may overestimate the copies of viral RNA result at the clinically relevant range of 1000 copies/ml, due to proviral DNA and intracellular RNA. The characteristics of the cobas® Plasma Separation Card (PSC) specimen are similar to fresh plasma (gold standard), so a better performance of HIV VL is expetected in PSC specimen and can be an alternative to DBS. This study aims to evaluate the performance of cobas® PSC for VL testing at primary health care facilities in Mozambique. METHODOLOGY: HIV-1 infected adults on ART were enrolled consecutively in two health facilities in Mozambique, between August 2018 and October 2018. Capillary and venous cobas® PSC, DBS and fresh plasma specimens were collected from each patient. All specimens were tested for VL using CAP/CTM v2.0. Sensitivity and specificity of viral load using DBS, capillary and venous PSC specimens were estimated. Viral load obtained in fresh plasma specimen was used as reference and a threshold of 1000 copies/ml was considered for the analyses.
resultsFrom the total 613 patients included for the study, 2444 specimens including DBS (613), plasma (613), venous cobas® PSC (609) and capillary cobas® PSC (609) were collected and 2407 results were obtained. Sensitivity and specificity of the VL using venous cobas®PSC specimen at 1000 copies/ml threshold were 99.8% and 98.1% respectively, whereas for capillary cobas® PSC sensitivity was 99.6% and specificity was 97.2%. For DBS VL, sensitivity was 96.9% and specificity was 81.8%. Misclassification rate was more prominent in DBS specimens (5.9%), but lower in venous and capillary cobas®PSC with a rate of 0.3% and 0.7% respectively.
conclusionThe cobas® PSC specimen has improved performance over DBS for more accurate VL testing aligned with plasma testing. The use of this specimen type can increase the rates of reliable VL results and this will improve the quality of VL monitoring of HIV-positive patients in low-income settings.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.