Evidence map›Paper›PMID 32372273›Full record

ArticleAnalytical and bioanalytical chemistry2020

Self-aligned microfluidic contactless dielectrophoresis device fabricated by single-layer imprinting on cyclic olefin copolymer.

Armita Salahi, Walter B Varhue, Vahid Farmehini, Alexandra R Hyler, Eva M Schmelz, Rafael V Davalos, Nathan S Swami

Abstract read
In one paragraph

Article in Analytical and bioanalytical chemistry, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Armita SalahiDepartment of Electrical and Computer Engineering, University of Virginia, Charlottesville, VA, 22904, USA.
Walter B VarhueDepartment of Electrical and Computer Engineering, University of Virginia, Charlottesville, VA, 22904, USA.
Vahid FarmehiniDepartment of Electrical and Computer Engineering, University of Virginia, Charlottesville, VA, 22904, USA.
Alexandra R HylerCytoRecovery, Inc., Blacksburg, VA, 24060, USA.
Eva M SchmelzDepartment of Human Nutrition, Foods and Exercise, Virginia Polytechnic Institute and State University, Blacksburg, VA, 24061, USA.
Rafael V DavalosDepartment of Biomedical Engineering & Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, VA, 24061, USA.
Nathan S SwamiDepartment of Electrical and Computer Engineering, University of Virginia, Charlottesville, VA, 22904, USA. nswami@virginia.edu.

Funding

The integrated Translational Health Research Institute of Virginia (iTHRIV): Using Data to Improve HealthUL1TR003015 · NCATS · UNIVERSITY OF VIRGINIA · PI BROWN, DONALD E, JOHNSTON, KAREN C. · 2019 to 2023
$20.3M
Optimizing Inter-Microbial Antagonisms to Control Clostridium Difficile InfectionR21AI130902 · NIAID · UNIVERSITY OF VIRGINIA · PI SWAMI, NATHAN, WARREN, CIRLE ALCANTARA · 2017 to 2018
$413k
Air Force Office of Scientific Research FA2386-18-1-4100CytoRecovery, Inc. Research ContractNCATS NIH HHS UL1 TR003015NCATS NIH HHS UL1TR003015NIAID NIH HHS R21 AI130902Virginia Catalyst VBHRC
6 · The paper itself

Abstract

The trapping and deflection of biological cells by dielectrophoresis (DEP) at field non-uniformities in a microfluidic device is often conducted in a contactless dielectrophoresis (cDEP) mode, wherein the electrode channel is in a different layer than the sample channel, so that field penetration through the interceding barrier causes DEP above critical cut-off frequencies. In this manner, through physical separation of the electrode and sample channels, it is possible to spatially modulate electric fields with no electrode-induced damage to biological cells in the sample channel. However, since this device requires interlayer alignment of the electrode to sample channel and needs to maintain a thin interceding barrier (~ 15 μm) over the entire length over which DEP is needed (~ 1 cm), variations in alignment and microstructure fidelity cause wide variations in cDEP trapping level and frequency response across devices. We present a strategy to eliminate interlayer alignment by fabricating self-aligned electrode and sample channels, simultaneously with the interceding barrier layer (14-μm width and 50-μm depth), using a single-layer imprint and bond process on cyclic olefin copolymer. Specifically, by designing support structures, we preserve fidelity of the high aspect ratio insulating posts in the sample channel and the interceding barrier between the sample and electrode channels over the entire device footprint (~ 1 cm). The device operation is validated based on impedance measurements to quantify field penetration through the interceding barrier and by DEP trapping measurements. The presented fabrication strategy can eventually improve cDEP device manufacturing protocols to enable more reproducible DEP performance. Graphical abstract.

Indexed as

Lab-On-A-Chip DevicesAlkenesElectrophoresisEquipment DesignPolymersAlkenesPolymersDielectrophoresisImprint lithographyMicrofabricationMicrofluidicsPolymers

Identifiers

PMID32372273
PMCPMC7325389

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.