Practical issues and limitations of brain attenuation correction on a simultaneous PET-MR scanner.
Article in EJNMMI physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Does a monoclonal antibody targeting immune cells affect glutamatergic level in schizophrenia? A multimodal PET/MRS brain imaging study.Neuropsychopharmacology : official publication of the American College of Neuropsychopharmacology · 2026Trial
- Beyond CT: Attenuation correction for stand-alone brain PET.Zeitschrift fur medizinische Physik · 2026Review
- The Dementias Platform UK PET/MR harmonisation and test-retest study: assessment of PET repeatability and reproducibility across the national network.European journal of nuclear medicine and molecular imaging · 2026Article
- Microglial activation, tau and amyloid deposition in TREM2 p.R47H carriers and mild cognitive impairment patients: a multi-modal/multi-tracer PET/MRI imaging study with influenza vaccine immune challenge.Journal of neuroinflammation · 2023Article
- A review of PET attenuation correction methods for PET-MR.EJNMMI physics · 2023Review
- Influences on PET Quantification and Interpretation.Diagnostics (Basel, Switzerland) · 2022Review
- Accuracy and precision of zero-echo-time, single- and multi-atlas attenuation correction for dynamic [EJNMMI physics · 2020Article
- [EJNMMI research · 2020Article
- Correction to: Practical issues and limitations of brain attenuation correction on a simultaneous PET-MR scanner.EJNMMI physics · 2020Article
Corrections and comments
- Erratum issued
Authors and funding
12 authors.
Funding
Abstract
backgroundDespite the advent of clinical PET-MR imaging for routine use in 2011 and the development of several methods to address the problem of attenuation correction, some challenges remain. We have identified and investigated several issues that might affect the reliability and accuracy of current attenuation correction methods when these are implemented for clinical and research studies of the brain. These are (1) the accuracy of converting CT Hounsfield units, obtained from an independently acquired CT scan, to 511 keV linear attenuation coefficients; (2) the effect of padding used in the MR head coil; (3) the presence of close-packed hair; (4) the effect of headphones. For each of these, we have examined the effect on reconstructed PET images and evaluated practical mitigating measures.
resultsOur major findings were (1) for both Siemens and GE PET-MR systems, CT data from either a Siemens or a GE PET-CT scanner may be used, provided the conversion to 511 keV μ-map is performed by the PET-MR vendor's own method, as implemented on their PET-CT scanner; (2) the effect of the head coil pads is minimal; (3) the effect of dense hair in the field of view is marked (> 10% error in reconstructed PET images); and (4) using headphones and not including them in the attenuation map causes significant errors in reconstructed PET images, but the risk of scanning without them may be acceptable following sound level measurements.
conclusionsIt is important that the limitations of attenuation correction in PET-MR are considered when designing research and clinical PET-MR protocols in order to enable accurate quantification of brain PET scans. Whilst the effect of pads is not significant, dense hair, the use of headphones and the use of an independently acquired CT-scan can all lead to non-negligible effects on PET quantification. Although seemingly trivial, these effects add complications to setting up protocols for clinical and research PET-MR studies that do not occur with PET-CT. In the absence of more sophisticated PET-MR brain attenuation correction, the effect of all of the issues above can be minimised if the pragmatic approaches presented in this work are followed.