Evidence map›Paper›PMID 32370759›Full record

ArticleBMC gastroenterology2020

Feasibility of using an led-probe in third-space endoscopy: a clinical study.

Oscar Víctor Hernández Mondragón, Raúl Zamarripa Mottú, Omar Solórzano Pineda, Raúl Alberto Gutierrez Aguilar, Luís Fernando García Contreras

Open access · goldAbstract readClinical Study
In one paragraph

Article in BMC gastroenterology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 53% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Oscar Víctor Hernández MondragónDivision of Endoscopy, Specialties Hospital, National Medical Center Century XXI, Cuauhtémoc Avenue 330, 06700, México City, Mexico. mondragonmd@yahoo.co.uk.
Raúl Zamarripa MottúDivision of Endoscopy, Specialties Hospital, National Medical Center Century XXI, Cuauhtémoc Avenue 330, 06700, México City, Mexico.
Omar Solórzano PinedaDivision of Endoscopy, Specialties Hospital, National Medical Center Century XXI, Cuauhtémoc Avenue 330, 06700, México City, Mexico.
Raúl Alberto Gutierrez AguilarDivision of Endoscopy, Specialties Hospital, National Medical Center Century XXI, Cuauhtémoc Avenue 330, 06700, México City, Mexico.
Luís Fernando García ContrerasDivision of Endoscopy, Specialties Hospital, National Medical Center Century XXI, Cuauhtémoc Avenue 330, 06700, México City, Mexico.
National Hospital · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThird-space endoscopy is a novel, safe, and effective method for treating different gastrointestinal conditions. However, several failed endoscopic procedures are attributed to incomplete myotomy. Lighting devices are used to prevent organic injuries. We aimed to investigate the feasibility of using a hand-made LED-probe (LP) in third-space procedures.

methodsThis prospective study was conducted in a tertiary-care center in Mexico between December 2016 and January 2019. We included peroral endoscopic myotomy (POEM) and gastric peroral endoscopic myotomy(G-POEM) procedures. Pseudoachalasia, peptic ulcer, normal gastric emptying scintigraphy (GES) and prepyloric tumors were excluded. LP was used to guide or confirm procedures. Clinical and procedural characteristics were recorded and analyzed.

resultsSeventy third-space procedures were included (42POEM,28G-POEM), with an average patient age of 46.7 ± 14.3 and 43.7 ± 10.1 years, respectively. For the POEM and G-POEM groups, respectively, 18/42(42.9%) and 13/28(46.7%) patients were males; median procedure times were 50 (interquartile range [IQR]: 38-71) and 60(IQR: 48-77) min, median LP placement times were 5(IQR: 4-6) and 6(IQR: 5-7) min, mild adverse events occurred in 4(9.4%) and 4(14.2%) of cases, and clinical success at 6 months occurred in 100 and 85.7% of cases. Integrated relaxation pressure (IRP) improved from 27.3 ± 10.8 to 9.5 ± 4.1 mmHg (p < 0.001); retention percentage at 4 h also improved. LP was successfully placed and adequate myotomy confirmed including 14.2 and 17.8% of POEM and G-POEM difficult patients.

conclusionsUsing an LP is promising and allows guiding during third-space procedures either for submucosal tunnel creation or myotomy confirmation, with excellent safety and efficacy in clinical practice.

Indexed as

AdultEndoscopy, Digestive SystemEsophageal AchalasiaFeasibility StudiesFemaleHumansLightingMaleMexicoMiddle AgedMouthMyotomyProspective StudiesPyloromyotomyTertiary Care CentersTreatment OutcomeGastric peroral endoscopic myotomyLED-probePeroral endoscopic myotomyThird-space endoscopy

Identifiers

PMID32370759
PMCPMC7201688
OpenAlexW3022891510

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.