ArticlePostepy w kardiologii interwencyjnej = Advances in interventional cardiology2020
Circulatory support with larger volume intra-aortic balloon pump vs. standard volume or no-balloon pump during high-risk percutaneous coronary interventions. A randomised study.
Article in Postepy w kardiologii interwencyjnej = Advances in interventional cardiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
- Intra-aortic balloon pump. A cheap device to protect CHIP?Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionPercutaneous coronary intervention in high-risk patients (HRPCI) is associated with increased risk of periprocedural complications such as hypotension and shock. Mechanical circulatory support devices may the bridge patient safely throughout the procedure and are often used in this setting.
aimWe assessed the outcomes of patients subjected to HRPCI and supported with intra-aortic balloon pump (IABP) of larger volume (MEGA) compared to standard volume (STRD) or no balloon support at all (CTRL). MATERIAL AND
methodsIn this single-centre, open-label, randomised, controlled trial, HRPCI patients were randomly assigned to three groups: MEGA, STRD, and CTRL in a 1 : 1 : 1 scheme. Screening failure patients were assigned to the registry (REG). Composite haemodynamic endpoint (CHEP) was assessed during the procedure and major adverse cardiac even (MACE)/safety endpoints up to 1-year follow-up (FU).
resultsA total of 36 patients were randomised (13 MEGA, 14 STRD, and 9 CTRL). The incidence of in-hospital MACE was observed in 23.1% of MEGA, 7.1% of STRD and 33.3% of CTRL (
conclusionsLarger volume intra-aortic balloon pump might be effective at reducing haemodynamic instability during HRPCI without a statistically significant effect on safety endpoints or MACE.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.