Trial reportThe international journal of cardiovascular imaging2020
Cardiac cine CT approaching 1 mSv: implementation and assessment of a 58-ms temporal resolution protocol.
Trial report in The international journal of cardiovascular imaging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 7 citations in OpenAlex.
- Retrospective Analysis of Incidental Myocardial Perfusion Defects on Non-ECG-Gated Contrast-Enhanced CT in Emergency Settings.Medicina (Kaunas, Lithuania) · 2026Article
- Article
- Minimal dose CT for left ventricular ejection fraction and combination with chest-abdomen-pelvis CT.European journal of radiology open · 2024Article
- Potential for Dose Reduction in CT-Derived Left Ventricular Ejection Fraction: A Simulation Study.Tomography (Ann Arbor, Mich.) · 2023Article
- Cardiac CT in CRT as a Singular Imaging Modality for Diagnosis and Patient-Tailored Management.Journal of clinical medicine · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
Abstract
Clinical use of cardiac cine CT imaging is limited by high radiation dose and low temporal resolution. To evaluate a low radiation dose, high temporal resolution cardiac cine CT protocol in human cardiac CT and phantom scans. CT scans of a circulating iodine target were reconstructed using the conventional single heartbeat half-scan (HS, approx. 175 ms temporal resolution) and the 3-heartbeat multi-segment (MS, approx. 58 ms) algorithms. Motion artifacts were quantified by the root-mean-square error (RMSE). Low-dose cardiac cine CT scans were performed in 55 subjects at a tube potential of 80 kVp and current of 80 mA. Image quality of HS and MS scans was assessed by blinded reader quality assessment, left ventricular (LV) free wall motion, and LV ejection rate. Motion artifacts in phantom scans were higher in HS than in MS reconstructions (RSME 188 and 117 HU, respectively; p = 0.001). Median radiation dose in human scans was 1.2 mSv. LV late diastolic filling was observed more frequently in MS than in HS images (42 vs. 26 subjects, respectively; p < 0.001). LV free wall systolic motion was more physiologic and had less error in MS than in HS reconstructions (sum-of-squared errors 34 vs. 45 mm
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.