Evidence map›Paper›PMID 32365071›Full record

ArticlePloS one2020

Determination of paramagnetic ferrous gel sensitivity in low energy x-ray beam produced by a miniature accelerator.

Yassir Ben Ahmed, Jérémy Coulaud, Soléakhena Ken, Laure Parent

Abstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yassir Ben AhmedDépartement d'Ingénierie et de Physique médicale, Institut Claudius Regaud (ICR), Institut Universitaire du Cancer de Toulouse-Oncopole (IUCT-O), Toulouse, France.ORCID 0000-0001-9758-9533
Jérémy CoulaudSIMAD LU50, Université Paul Sabatier Toulouse III, Castres, Toulouse, France.
Soléakhena KenDépartement d'Ingénierie et de Physique médicale, Institut Claudius Regaud (ICR), Institut Universitaire du Cancer de Toulouse-Oncopole (IUCT-O), Toulouse, France.
Laure ParentDépartement d'Ingénierie et de Physique médicale, Institut Claudius Regaud (ICR), Institut Universitaire du Cancer de Toulouse-Oncopole (IUCT-O), Toulouse, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The INTRABEAM Carl Zeiss Surgical system (Oberkochen, Germany) is a miniature accelerator producing low energy photons (50 keV maximum). The published dosimetric characterization of the INTRABEAM was based on detectors (radiochromic films or ionization chambers) not allowing measuring the absorbed dose in the first millimeters of the irradiated medium, where the dose is actually prescribed. This study aims at determining with Magnetic Resonance Imaging (MRI) the sensitivity of a paramagnetic gel in order to measure the dose deposit produced with the INTRABEAM from 0 to 20 mm. Although spherical applicators are mostly used with the INTRABEAM system for breast applications, this study focuses on surface applicators that are of interest for cutaneous carcinomas. The irradiations at 12 different dose levels (between 2 Gy and 50 Gy at the gel surface) were performed with the INTRABEAM and a 4 cm surface applicator. The gel used in this study is a new « sensitive » material. In order to compare gel sensitivity at low energy with high energy, gels were irradiated by an 18 MV photon beam produced by a Varian Clinac 2100 CD. T2 weighted multi echo MRI sequences were performed with 16 echo times. The T2 signal versus echo times was fitted with a mono-exponential function with 95% confidence interval. The calibration curve determined at low energy is a linear function (r2 = 0.9893) with a sensitivity of 0.0381 s-1.Gy-1, a similar linear function was obtained at high energy (0.0372 s-1.Gy-1 with r2 = 0.9662). The calibration curve at low energy was used to draw isodose maps from the MR images. The PDD (Percent Depth Dose) determined in the gel is within 5%-1mm of the ionization chamber PDD except for one point. The dosimetric sensitivity of this new paramagnetic ferrous gel was determined with MRI measurements. It allowed measuring the dose distribution specifically in the first millimeters for an irradiation with the INTRABEAM miniature accelerator equipped with a surface applicator.

Indexed as

Ferrous CompoundsGelsMagnetic PhenomenaMiniaturizationParticle AcceleratorsRadiation DosageRadiometrySignal-To-Noise RatioX-RaysFerrous CompoundsGels

Identifiers

PMID32365071
PMCPMC7197784

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.