Evidence map›Paper›PMID 32365014›Full record

ArticleIEEE transactions on bio-medical engineering2021

Magnetic-Resonance-Based Electrical Property Mapping Using Global Maxwell Tomography With an 8-Channel Head Coil at 7 Tesla: A Simulation Study.

Ilias I Giannakopoulos, Jose E C Serralles, Luca Daniel, Daniel K Sodickson, Athanasios G Polimeridis, Jacob K White, Riccardo Lattanzi

Abstract read
In one paragraph

Article in IEEE transactions on bio-medical engineering, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Electrical properties basedMagnetic resonance in medicine · 2025
    Article
  5. Article
  6. Article
  7. PIFON-EPT: MR-Based Electrical Property Tomography Using Physics-Informed Fourier Networks.IEEE journal on multiscale and multiphysics computational techniques · 2024
    Article
  8. Article
  9. MARIE 2.0: A Perturbation Matrix Based Patient-Specific MRI Field Simulator.IEEE transactions on bio-medical engineering · 2023
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Electrical Properties Tomography: A Methodological Review.Diagnostics (Basel, Switzerland) · 2021
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ilias I Giannakopoulos
Jose E C Serralles
Luca Daniel
Daniel K Sodickson
Athanasios G Polimeridis
Jacob K White
Riccardo Lattanzi

Funding

TR&D 4: Revealing Microstructure: Biophysical modeling and validation for discovery and clinical careP41EB017183 · NIBIB · NEW YORK UNIVERSITY SCHOOL OF MEDICINE · PI Dmitry S Novikov · 2014 to 2026
$19.3M
Novel Software Tools for Rational Design and Assessment of MR CoilsR01EB024536 · NIBIB · NEW YORK UNIVERSITY SCHOOL OF MEDICINE · PI Riccardo Lattanzi · 2017 to 2026
$5.1M
NIBIB NIH HHS P41 EB017183NIBIB NIH HHS R01 EB024536
6 · The paper itself

Abstract

objectiveGlobal Maxwell Tomography (GMT) is a recently introduced volumetric technique for noninvasive estimation of electrical properties (EP) from magnetic resonance measurements. Previous work evaluated GMT using ideal radiofrequency (RF) excitations. The aim of this simulation study was to assess GMT performance with a realistic RF coil.

methodsWe designed a transmit-receive RF coil with 8 decoupled channels for 7T head imaging. We calculated the RF transmit field ( B

resultsCoil tuning/decoupling remained relatively stable when the coil was loaded with different head models. Mean error in EP estimation changed from [Formula: see text] to [Formula: see text] and from [Formula: see text] to [Formula: see text] for relative permittivity and conductivity, respectively, when changing head model without re-tuning the coil. Results slightly improved when an SVD-based RF shimming algorithm was applied, in place of excitation with one coil at a time. Despite errors in EP, RF transmit field ( B

conclusionThis work demonstrates that GMT can reliably reconstruct EP in realistic simulated scenarios using a tailored 8-channel RF coil design at 7T. Future work will focus on construction of the coil and optimization of GMT's robustness to noise, to enable in-vivo GMT experiments. SIGNIFICANCE: GMT could provide accurate estimations of tissue EP, which could be used as biomarkers and could enable patient-specific estimation of RF power deposition, which is an unsolved problem for ultra-high-field magnetic resonance imaging.

Indexed as

Magnetic Resonance SpectroscopyTomographyEquipment DesignHumansMagnetic Resonance ImagingPhantoms, ImagingRadio Waves

Identifiers

PMID32365014
PMCPMC7606812

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.