ArticleIEEE transactions on bio-medical engineering2021
Magnetic-Resonance-Based Electrical Property Mapping Using Global Maxwell Tomography With an 8-Channel Head Coil at 7 Tesla: A Simulation Study.
Article in IEEE transactions on bio-medical engineering, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- An Open-Source Software Toolbox for Rapid Radiofrequency Coil Design and Evaluation in MRI.Magnetic resonance in medicine · 2026Article
- Comparative Assessment of Graglia-Wilton-Peterson and Rao-Wilton-Glisson Basis Functions for Radiofrequency Coil Modeling in Magnetic Resonance Imaging.IEEE journal on multiscale and multiphysics computational techniques · 2026Article
- Global Maxwell Tomography Using the Volume-Surface Integral Equation for Improved Estimation of Electrical Properties.IEEE transactions on bio-medical engineering · 2025Article
- Electrical properties basedMagnetic resonance in medicine · 2025Article
- MR electrical properties mapping using vision transformers and canny edge detectors.Magnetic resonance in medicine · 2025Article
- Computational methods for the estimation of ideal current patterns in realistic human models.Magnetic resonance in medicine · 2024Article
- PIFON-EPT: MR-Based Electrical Property Tomography Using Physics-Informed Fourier Networks.IEEE journal on multiscale and multiphysics computational techniques · 2024Article
- Data-driven electrical conductivity brain imaging using 3 T MRI.Human brain mapping · 2023Article
- MARIE 2.0: A Perturbation Matrix Based Patient-Specific MRI Field Simulator.IEEE transactions on bio-medical engineering · 2023Article
- Repeatability and Reproducibility Uncertainty in Magnetic Resonance-Based Electric Properties Tomography of a Homogeneous Phantom.Tomography (Ann Arbor, Mich.) · 2023Article
- A Hybrid Volume-Surface Integral Equation Method for Rapid Electromagnetic Simulations in MRI.IEEE transactions on bio-medical engineering · 2023Article
- Novel Numerical Basis Sets for Electromagnetic Field Expansion in Arbitrary Inhomogeneous Objects.IEEE transactions on antennas and propagation · 2022Article
- Compression of volume-surface integral equation matrices via Tucker decomposition for magnetic resonance applications.IEEE transactions on antennas and propagation · 2022Article
- Electrical Properties Tomography: A Methodological Review.Diagnostics (Basel, Switzerland) · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
objectiveGlobal Maxwell Tomography (GMT) is a recently introduced volumetric technique for noninvasive estimation of electrical properties (EP) from magnetic resonance measurements. Previous work evaluated GMT using ideal radiofrequency (RF) excitations. The aim of this simulation study was to assess GMT performance with a realistic RF coil.
methodsWe designed a transmit-receive RF coil with 8 decoupled channels for 7T head imaging. We calculated the RF transmit field ( B
resultsCoil tuning/decoupling remained relatively stable when the coil was loaded with different head models. Mean error in EP estimation changed from [Formula: see text] to [Formula: see text] and from [Formula: see text] to [Formula: see text] for relative permittivity and conductivity, respectively, when changing head model without re-tuning the coil. Results slightly improved when an SVD-based RF shimming algorithm was applied, in place of excitation with one coil at a time. Despite errors in EP, RF transmit field ( B
conclusionThis work demonstrates that GMT can reliably reconstruct EP in realistic simulated scenarios using a tailored 8-channel RF coil design at 7T. Future work will focus on construction of the coil and optimization of GMT's robustness to noise, to enable in-vivo GMT experiments. SIGNIFICANCE: GMT could provide accurate estimations of tissue EP, which could be used as biomarkers and could enable patient-specific estimation of RF power deposition, which is an unsolved problem for ultra-high-field magnetic resonance imaging.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials