Evidence map›Paper›PMID 32363474›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2020

Hip capsular strain varies between ligaments dependent on both hip position- and applied rotational force.

Timothy A Burkhart, Pardis Baha, Alexandra Blokker, Ivailo Petrov, David W Holdsworth, Maria Drangova, Alan Getgood, Ryan M Degen

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Capsular Management During Hip Arthroscopy.Current reviews in musculoskeletal medicine · 2023
    Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Timothy A BurkhartDepartment of Mechanical and Materials Engineering, Western University, London, ON, Canada.
Pardis BahaDepartment of Mechanical and Materials Engineering, Western University, London, ON, Canada.
Alexandra BlokkerDepartment of Mechanical and Materials Engineering, Western University, London, ON, Canada.
Ivailo PetrovBone and Joint Institute, Western University, London, ON, Canada.
David W HoldsworthBone and Joint Institute, Western University, London, ON, Canada.
Maria DrangovaBone and Joint Institute, Western University, London, ON, Canada.
Alan GetgoodBone and Joint Institute, Western University, London, ON, Canada.
Ryan M DegenBone and Joint Institute, Western University, London, ON, Canada. Ryan.degen@lhsc.on.ca.ORCID http://orcid.org/0000-0001-9981-6074
Western University · CA

Funding

Academic Medical Organization of Southwestern Ontario #F17-004Smith and Nephew Orthopaedics A17-ASDUS-GR-598
6 · The paper itself

Abstract

purposeTo noninvasively characterize the ligament strain in the hip capsule using a novel CT-based imaging technique.

methodsThe superior iliofemoral ligament (SIFL), inferior iliofemoral ligament (IIFL), ischiofemoral ligament (IFL) and pubofemoral ligament (PFL) were identified and beaded in seven cadavers. Specimens were mounted on a joint motion simulator within an O-arm CT scanner in - 15°, 0°, 30°, 60°, and 90° of flexion. 3 Nm of internal rotation (IR) and external rotation (ER) were applied and CT scans obtained. Strains were calculated by comparing bead separation in loaded and unloaded conditions. Repeated-measures ANOVA was used to evaluate differences in strain within ligaments between hip positions.

resultsFor the SIFL, strain significantly decreased in IR at 30° (p = 0.045) and 60° (p = 0.043) versus 0°. For ER, there were no significant position-specific changes in strain (n.s.). For the IIFL, strain decreased in IR and increased in ER with no significant position-specific differences. For the IFL, strain increased with IR and decreased with ER with no significant position-specific differences. Finally, in the PFL there was a significant flexion angle-by-load interaction (p < 0.001; ES = 0.566), with peak strains noted at 60˚, however pair-wise comparisons failed to identify significant differences between positions (n.s.). Strain decreased in ER, with no significant position-specific differences.

conclusionThe SIFL and IIFL limit hip external rotation with greater effect in higher flexion angles, while the IFL and PFL limit hip internal rotation. Following hip arthroscopy, consideration should be given to restricting external rotation as traditional capsulotomies cause injury to the SIFL and IIFL.

Indexed as

AgedArthroscopyBiomechanical PhenomenaCadaverHip JointHumansImaging, Three-DimensionalLigaments, ArticularRange of Motion, ArticularRotationTomography, X-Ray ComputedCapsuleHipStrain

Identifiers

PMID32363474
OpenAlexW3021085112

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.