Evidence map›Paper›PMID 32363254›Full record

ArticlePathogens & immunity2020

Effectiveness of Ultraviolet-C Light and a High-Level Disinfection Cabinet for Decontamination of N95 Respirators.

Jennifer L Cadnum, Daniel F Li, Sarah N Redmond, Amrita R John, Basya Pearlmutter, Curtis J Donskey

Abstract read
In one paragraph

Article in Pathogens & immunity, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 58 papers, 8 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
58citing papers in PubMed, 8 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

58 citing papers in PubMed, 8 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. The COVID-19 pandemic and N95 masks: reusability and decontamination methods.Antimicrobial resistance and infection control · 2021
    Pooled it
  6. Pooled it
  7. Pooled it
  8. Pooled it
  9. Article
  10. Observational
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Supercritical COThe Science of the total environment · 2022
    Article
  19. Review
  20. Is Peracetic Acid Fumigation Effective in Public Transportation?International journal of environmental research and public health · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jennifer L CadnumResearch Service; Louis Stokes Cleveland VA Medical Center; Cleveland, Ohio.
Daniel F LiResearch Service; Louis Stokes Cleveland VA Medical Center; Cleveland, Ohio.
Sarah N RedmondGeriatric Research, Education, and Clinical Center; Louis Stokes Cleveland VA Medical Center; Cleveland, Ohio.
Amrita R JohnDepartment of Medicine; University Hospitals Cleveland Medical Center; Cleveland, Ohio.
Basya PearlmutterResearch Service; Louis Stokes Cleveland VA Medical Center; Cleveland, Ohio.
Curtis J DonskeyGeriatric Research, Education, and Clinical Center; Louis Stokes Cleveland VA Medical Center; Cleveland, Ohio.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundShortages of personal protective equipment (PPE) including N95 respirators are an urgent concern in the setting of the global COVID-19 pandemic. Decontamination of PPE could be useful to maintain adequate supplies, but there is uncertainty regarding the efficacy of decontamination technologies.

methodsA modification of the American Society for Testing and Materials standard quantitative carrier disk test method (ASTM E-2197-11) was used to examine the effectiveness of 3 methods, including ultraviolet-C (UV-C) light, a high-level disinfection cabinet that generates aerosolized peracetic acid and hydrogen peroxide, and dry heat at 70°C for 30 minutes. We assessed the decontamination of 3 commercial N95 respirators inoculated with methicillin-resistant

resultsUV-C administered as a 1-minute cycle in a UV-C box or a 30-minute cycle by a room decontamination device reduced contamination but did not meet criteria for decontamination of the viruses from all sites on the N95s. The high-level disinfection cabinet was effective for decontamination of the N95s and achieved disinfection with an extended 31-minute cycle. Dry heat at 70°C for 30 minutes was not effective for decontamination of the bacteriophages.

conclusionsUV-C could be useful to reduce contamination on N95 respirators. However, the UV-C technologies studied did not meet pre-established criteria for decontamination under the test conditions used. The high-level disinfection cabinet was more effective and met criteria for disinfection with an extended cycle.

Indexed as

decontaminationN95 respiratorperacetic acidSARS-CoV-2Ultraviolet-C

Identifiers

PMID32363254
PMCPMC7192214

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked