ArticleInternational journal for numerical methods in biomedical engineering2020
A pilot in silico modeling-based study of the pathological effects on the biomechanical function of tricuspid valves.
Article in International journal for numerical methods in biomedical engineering, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
23 citing papers in PubMed, 22 citations in OpenAlex.
- Personalized tricuspid valve modeling predicts regurgitation biomechanical repair and double‑orifice flow.Physical and engineering sciences in medicine · 2026Article
- Effect of Parametric Variation of Chordae Tendineae Structure on Simulated Atrioventricular Valve Closure.Annals of biomedical engineering · 2026Article
- A modelling study of right ventricular growth with valvular regurgitation.Biomechanics and modeling in mechanobiology · 2026Article
- Chordae Rupture Alters Tricuspid Valve Leaflet Biomechanics.Cardiovascular engineering and technology · 2026Article
- State-space formulations to understand the nonlinear viscoelastic mechanical behavior of tricuspid valve chordae tendineae.Applied mathematical modelling · 2026Article
- ValveFit: An analysis-suitable B-spline-based surface fitting framework for patient-specific modeling of tricuspid valves.Computer methods in applied mechanics and engineering · 2026Article
- Tricuspid valve edge-to-edge repair simulations are highly sensitive to annular boundary conditions.Journal of the mechanical behavior of biomedical materials · 2025Article
- HETEROGENEOUS PERIDYNAMIC NEURAL OPERATORS: DISCOVER BIOTISSUE CONSTITUTIVE LAW AND MICROSTRUCTURE FROM DIGITAL IMAGE CORRELATION MEASUREMENTS.Foundations of data science (Springfield, Mo.) · 2025Article
- FEBio FINESSE: An Open-Source Finite Element Simulation Approach to Estimate In Vivo Heart Valve Strains Using Shape Enforcement.Annals of biomedical engineering · 2025Article
- Geometric data of commercially available tricuspid valve annuloplasty devices.Data in brief · 2024Article
- The effects of leaflet material properties on the simulated function of regurgitant mitral valves.Journal of the mechanical behavior of biomedical materials · 2023Article
- The Effects of leaflet material properties on the simulated function of regurgitant mitral valves.ArXiv · 2023Article
- Tricuspid Valve Regurgitation in Hypoplastic Left Heart Syndrome: Current Insights and Future Perspectives.Journal of cardiovascular development and disease · 2023Review
- Benchtop characterization of the tricuspid valve leaflet pre-strains.Acta biomaterialia · 2022Article
- Texas TriValve 1.0 : a reverse‑engineered, open model of the human tricuspid valve.Engineering with computers · 2022Article
- A Computational Framework for Atrioventricular Valve Modeling Using Open-Source Software.Journal of biomechanical engineering · 2022Article
- Clinical Impact of Computational Heart Valve Models.Materials (Basel, Switzerland) · 2022Review
- Viscoelastic modelling of the tricuspid valve chordae tendineae tissue.Applied mathematical modelling · 2022Article
- AnData in brief · 2021Article
- Parameterization, geometric modeling, and isogeometric analysis of tricuspid valves.Computer methods in applied mechanics and engineering · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 5 institutions in 3 countries.
Funding
Abstract
Current clinical assessment of functional tricuspid valve regurgitation relies on metrics quantified from medical imaging modalities. Although these clinical methodologies are generally successful, the lack of detailed information about the mechanical environment of the valve presents inherent challenges for assessing tricuspid valve regurgitation. In the present study, we have developed a finite element-based in silico model of one porcine tricuspid valve (TV) geometry to investigate how various pathological conditions affect the overall biomechanical function of the TV. There were three primary observations from our results. Firstly, the results of the papillary muscle (PM) displacement study scenario indicated more pronounced changes in the TV biomechanical function. Secondly, compared to uniform annulus dilation, nonuniform dilation scenario induced more evident changes in the von Mises stresses (83.8-125.3 kPa vs 65.1-84.0 kPa) and the Green-Lagrange strains (0.52-0.58 vs 0.47-0.53) for the three TV leaflets. Finally, results from the pulmonary hypertension study scenario showed opposite trends compared to the PM displacement and annulus dilation scenarios. Furthermore, various chordae rupture scenarios were simulated, and the results showed that the chordae tendineae attached to the TV anterior and septal leaflets may be more critical to proper TV function. This in silico modeling-based study has provided a deeper insight into the tricuspid valve pathologies that may be useful, with moderate extensions, for guiding clinical decisions. NOVELTY STATEMENT: The novelties of the research are summarized below: A comprehensive in silico pilot study of how isolated functional tricuspid regurgitation pathologies and ruptured chordae tendineae would alter the tricuspid valve function; An extensive analysis of the tricuspid valve function, including mechanical quantities (eg, the von Mises stress and the Green-Lagrange strain) and clinically-relevant geometry metrics (eg, the tenting area and the coaptation height); and A developed computational modeling pipeline that can be extended to evaluate patient-specific tricuspid valve geometries and enhance the current clinical diagnosis and treatment of tricuspid regurgitation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.