Evidence map›Paper›PMID 32361857›Full record

ArticleInternational journal of computer assisted radiology and surgery2020

Assessment and application of the coherent point drift algorithm to augmented reality surgical navigation for laparoscopic partial nephrectomy.

Xiaohui Zhang, Tianmiao Wang, Xuebin Zhang, Yinghao Zhang, Junchen Wang

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Xiaohui ZhangSchool of Mechanical Engineering and Automation, Beihang University, Beijing, China.
Tianmiao WangSchool of Mechanical Engineering and Automation, Beihang University, Beijing, China.
Xuebin ZhangDepartment of Urology, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China.
Yinghao ZhangSchool of Mechanical Engineering and Automation, Beihang University, Beijing, China.
Junchen WangSchool of Mechanical Engineering and Automation, Beihang University, Beijing, China. wangjunchen@buaa.edu.cn.ORCID http://orcid.org/0000-0002-0916-9932

Funding

National Natural Science Foundation of China 61701014National Natural Science Foundation of China 61911540075
6 · The paper itself

Abstract

purposeThe surface-based registration approach to laparoscopic augmented reality (AR) has clear advantages. Nonrigid point-set registration paves the way for surface-based registration. Among current non-rigid point set registration methods, the coherent point drift (CPD) algorithm is rarely used because of two challenges: (1) volumetric deformation is difficult to predict, and (2) registration from intraoperative visible tissue surface to whole anatomical preoperative model is a "part-to-whole" registration that CPD cannot be applied directly to. We preliminarily applied CPD on surgical navigation for laparoscopic partial nephrectomy (LPN). However, it introduces normalization errors and lacks navigation robustness. This paper presents important advances for more effectively applying CPD to LPN surgical navigation while attempting to quantitatively evaluate the accuracy of CPD-based surgical navigation.

methodsFirst, an optimized volumetric deformation (Op-VD) algorithm is proposed to achieve accurate prediction of volume deformation. Then, a projection-based partial selection method is presented to conveniently and robustly apply the CPD to LPN surgical navigation. Finally, kidneys with different deformations in vitro, phantom and in vivo experiments are performed to evaluate the accuracy and effectiveness of our approach.

resultsThe average root-mean-square error of volume deformation was refined to 0.84 mm. The mean target registration error (TRE) of the surface and inside markers in the in vitro experiments decreased to 1.51 mm and 1.29 mm, respectively. The robustness and precision of CPD-based navigation were validated in phantom and in vivo experiments, and the mean navigation TRE of the phantom experiments was found to be [Formula: see text] mm.

conclusionAccurate volumetric deformation and robust navigation results can be achieved in AR navigation of LPN by using surface-based registration with CPD. Evaluation results demonstrate the effectiveness of our proposed methods while showing the clinical application potential of CPD. This work has important guiding significance for the application of the CPD in laparoscopic AR.

Indexed as

Augmented RealityAlgorithmsHumansKidneyLaparoscopyNephrectomyPhantoms, ImagingSurgery, Computer-AssistedCoherent point drift (CPD)Nonrigid registrationSurface-based registrationSurgical navigation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.