Cone-beam breast computed tomography using ultra-fast image reconstruction with constrained, total-variation minimization for suppression of artifacts.
Article in Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Development and performance evaluation of an upright dedicated cone-beam breast CT system.Medical physics · 2026Article
- Soft-tissue lesion and microcalcification detectability in cone-beam breast CT: cascaded system analysis.Journal of medical imaging (Bellingham, Wash.) · 2025Article
- Simultaneous reduction of radiation dose and scatter-to-primary ratio using a truncated detector and advanced algorithms for dedicated cone-beam breast CT.Biomedical physics & engineering express · 2025Article
- Maximizing microcalcification detectability in low-dose dedicated cone-beam breast CT: parallel cascades-based theoretical analysis.Journal of medical imaging (Bellingham, Wash.) · 2024Article
- An attenuation field network for dedicated cone beam breast CT with short scan and offset detector geometry.Scientific reports · 2024Article
- Dedicated Cone-Beam Breast CT: Reproducibility of Volumetric Glandular Fraction with Advanced Image Reconstruction Methods.Tomography (Ann Arbor, Mich.) · 2023Article
- Cone-beam breast CT using an offset detector: effect of detector offset and image reconstruction algorithm.Physics in medicine and biology · 2022Article
- Dedicated breast CT: state of the art-Part I. Historical evolution and technical aspects.European radiology · 2022Review
- Breast Cancer Screening: Opportunities and Challenges with Fully 3D Tomographic X-Ray Imaging.Bridge (Washington, D.C. : 1969) · 2022Article
- Radiation dosimetry of a clinical prototype dedicated cone-beam breast CT system with offset detector.Medical physics · 2021Article
- A residual dense network assisted sparse view reconstruction for breast computed tomography.Scientific reports · 2020Article
- Sparse-view, short-scan, dedicated cone-beam breast computed tomography: image quality assessment.Biomedical physics & engineering express · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Compressed sensing based iterative reconstruction algorithms for computed tomography such as adaptive steepest descent-projection on convex sets (ASD-POCS) are attractive due to their applicability in incomplete datasets such as sparse-view data and can reduce radiation dose to the patients while preserving image quality. Although IR algorithms reduce image noise compared to analytical Feldkamp-Davis-Kress (FDK) algorithm, they may generate artifacts, particularly along the periphery of the object. One popular solution is to use finer image-grid followed by down-sampling. This approach is computationally intensive but may be compensated by reducing the field of view. Our proposed solution is to replace the algebraic reconstruction technique within the original ASD-POCS by ordered subsets-simultaneous algebraic reconstruction technique (OS-SART) and with initialization using FDK image. We refer to this method as Fast, Iterative, TV-Regularized, Statistical reconstruction Technique (FIRST). In this study, we investigate FIRST for cone-beam dedicated breast CT with large image matrix. The signal-difference to noise ratio (SDNR), the difference of the mean value and the variance of adipose and fibroglandular tissues for both FDK and FIRST reconstructions were determined. With FDK serving as the reference, the root-mean-square error (RMSE), bias, and the full-width at half-maximum (FWHM) of microcalcifications in two orthogonal directions were also computed. Our results suggest that FIRST is competitive to the finer image-grid method with shorter reconstruction time. Images reconstructed using the FIRST do not exhibit artifacts and outperformed FDK in terms of image noise. This suggests the potential of this approach for radiation dose reduction in cone-beam breast CT.