Evidence map›Paper›PMID 32358714›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2020

Achievable pin spanning angulation in anterosuperior pelvic external fixation.

Benjamin Young, Drayton Daily, Clarence Kee, Kevin Perry, Massimo Max Morandi, R Shane Barton, Giovanni F Solitro

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Benjamin YoungDepartment of Orthopaedic Surgery, Louisiana State University Health Sciences Center, 1501 Kings Highway, P.O. Box 33932, Shreveport, LA, USA.
Drayton DailyDepartment of Orthopaedic Surgery, Louisiana State University Health Sciences Center, 1501 Kings Highway, P.O. Box 33932, Shreveport, LA, USA.
Clarence KeeDepartment of Orthopaedic Surgery, Louisiana State University Health Sciences Center, 1501 Kings Highway, P.O. Box 33932, Shreveport, LA, USA.
Kevin PerryDepartment of Orthopaedic Surgery, Louisiana State University Health Sciences Center, 1501 Kings Highway, P.O. Box 33932, Shreveport, LA, USA.
Massimo Max MorandiDepartment of Orthopaedic Surgery, Louisiana State University Health Sciences Center, 1501 Kings Highway, P.O. Box 33932, Shreveport, LA, USA.
R Shane BartonDepartment of Orthopaedic Surgery, Louisiana State University Health Sciences Center, 1501 Kings Highway, P.O. Box 33932, Shreveport, LA, USA.
Giovanni F SolitroDepartment of Orthopaedic Surgery, Louisiana State University Health Sciences Center, 1501 Kings Highway, P.O. Box 33932, Shreveport, LA, USA. gsolit@lsuhsc.edu.ORCID http://orcid.org/0000-0003-0994-5724

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionPelvic external fixation using anterosuperior pins provides a quick method of stabilization without necessitating fluoroscopic guidance. Various locations, depths, and inclinations have been cited for external fixator pins; however, the existing literature lacks clear indications for the angular difference between pins. Thus, we aimed to determine the greatest degree of sagittal pin spanning angulation (SPSA) between two iliac crest pins and how intraosseous depth (ID) affects these angulations. MATERIALS AND

methodsA newly developed computer algorithm produced cross sections of 3D pelvic reconstructions in the sagittal plane in 5° increments. Computer-generated pins with IDs of 60, 75, and 90 mm were positioned in 5° increments transversely. Pins were assessed for cortical containment to define values for SPSA and transverse pin spanning angulation (TPSA).

resultsA bimodal distribution revealed varying degrees of insertion frequency and SPSA, cranially and caudally. The caudal distribution exhibited greater cortical containment with larger values for SPSA and TPSA. The highest insertion frequency (85.7%) and largest SPSA (155°) were observed for the 60-mm ID. Increasing ID resulted in further bony penetration and smaller values for SPSA and TPSA.

conclusionsExpanding the degree of SPSA between inserted pins in anterosuperior pelvic external fixation can be challenging due to the thinning of the iliac wing, which affords a narrow corridor for intraosseous pin containment. An ID of 60 mm allows larger degrees of SPSA while maintaining higher rates of cortical pin containment when compared to pins with greater IDs.

Indexed as

External FixatorsPelvic BonesBone NailsFracture FixationHumansIliumAnterosuperiorBiomechanical stabilityExternal fixationPelvisStabilizationTrauma

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.